Color Doppler detection of multiple ventricular septal defects.

نویسندگان

  • A Ludomirsky
  • J C Huhta
  • G W Vick
  • D J Murphy
  • D A Danford
  • W R Morrow
چکیده

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricular septal defects with two-dimensional color flow mapping was compared with detection by standard two-dimensional imaging and Doppler. Both techniques were compared with four-chamber left ventricular angiography. Fifty-one patients (age 3 months to 25 years, mean 5.6 years) were studied. Eighteen had solitary ventricular septal defects, 18 had multiple ventricular septal defects, and 15 patients with intact ventricular septum served as a control group. At least one ventricular septal defect was detected by color Doppler and two-dimensional/Doppler methods in all patients with ventricular septal defect proved by angiography with no false positives. In the detection of multiple ventricular septal defects, the sensitivity of color Doppler was 72% and that of two-dimensional/Doppler was 38% (100% specificity in both). Color Doppler failed to identify multiple ventricular septal defects in five patients (two weighing less than 4 kg and three with reduced pulmonary blood flow). However, no large additional muscular defects were missed by imaging and color Doppler. Color Doppler is useful for the detection of ventricular septal defects and has higher sensitivity than two-dimensional/Doppler for multiple ventricular septal defects. The contribution of color Doppler appears to be in the detection of additional small muscular ventricular septal defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS CONGENITAL HEART DISEASE Color Doppler detection of multiple ventricular septal defects

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricu...

متن کامل

High prevalence of muscular ventricular septal defect in neonates.

OBJECTIVES This study sought to use echocardiography to evaluate the prevalence of muscular ventricular septal defect in neonates. BACKGROUND Ventricular septal defect is usually asymptomatic and closes spontaneously. An increase in its prevalence has been noted recently. One reason is the improved detection of small defects, especially with the increased used of echocardiography. Therefore, ...

متن کامل

Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.

Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiog...

متن کامل

Huge interatrial septal aneurysm with fenestrated atrial septal defect.

Figure 1. Transthoracic four-chamber view (A) showing interatrial septal aneurysm (arrow) extending to the right ventricular inflow and left-to-right shunt (dotted arrow) with color Doppler (B). Transesophageal four-chamber (C) and short-axis (D) views showing huge interatrial septal aneurysm (asterisks). Multiple atrial septal defects (yellow arrows) were seen with color Doppler on four-chambe...

متن کامل

Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations.

The M-mode echocardiographic findings of ventricular septal defect (VSD) are nonspecific. A specific pulsed Doppler echocardiographic (PDE) diagnosis of VSD can be made by following the turbulent VSD jet through the septum. To assess the sensitivity, specificity and limitations of PDE diagnosis of VSD, 105 children undergoing cardiac catheterization were examined by PDE. These children had a va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 74 6  شماره 

صفحات  -

تاریخ انتشار 1986