Error-Tolerant RF Litz Coils for Double-Resonance MRI
نویسندگان
چکیده
Introduction: A new class of NMR/MRI rf volume coils is being developed that permits improved tuning range, tuning stability, B1 homogeneity, sensitivity, and ease of use compared to birdcages over a wide range of practical conditions, esp ecially for double-resonance microscopy and wraparound flexible applications. They are denoted litz coils (after the German word for "braided'), as the desired flux transparency is achieved using woven foil with insulated crossovers. While it has been shown that the low-order quadrature and homog eneity errors in the birdcage can be corrected with just two trimmer capacitors [1], the remaining rungcurrent errors may exceed 30% and can only be addressed by a complex tuning procedure [2]. Moreover, the magnetic filling factor ηF of bir dcages with closely spaced external shields is us ually b elow 5%.
منابع مشابه
High-Throughput RF Coils for High-Field MRI
Improvements in signal to noise ratio (SNR) and ease of use of magnetic resonance imaging (MRI) rf coils are needed to improve image quality and patient throughput in high-field MRI. The goal of this Phase II project is to continue the development of novel rf coil topologies and rf balancing circuits that have demonstrated substantially improved technical performance, reduced cost, and greatly ...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملRadiation induced currents in MRI RF coils
The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integ...