Flicker electroretinograms of eyes with cataract recorded with RETeval system before and after mydriasis
نویسندگان
چکیده
Purpose The aim of this study is to determine the effect of pupil size of eyes with cataracts on the flicker electroretinograms (ERGs) elicited and recorded with the RETeval system. Patients and methods Forty-one eyes of 41 patients (mean age, 76.5±7.3 years) that had grade 2 nuclear or cortical cataract without any other abnormalities were studied. Flicker ERGs were recorded before and after mydriatic drops instillation. The ERGs were elicited by the white light delivered at the frequency of 28.3 Hz and intensities of 2, 8, and 32 Td-s. The amplitudes and the implicit times of the flicker ERGs before and after mydriasis were compared. Results There were no significant differences between the amplitudes before and after mydriasis (P=0.35, 2 Td-s; P=0.31, 8 Td-s; P=0.50, 32 Td-s). There were also no significant differences between the implicit times before and after mydriasis (P=0.86, 2 Td-s; P=0.98, 8 Td-s; P=0.95, 32 Td-s). The mean amplitudes and implicit times of the nuclear and cortical cataracts groups before the mydriasis were also not significantly different from those after mydriasis for all stimulus intensities. Conclusion The lack of significant differences in the amplitudes and the implicit times of the flicker ERG of cataractous eyes before and after mydriasis indicated that the RETeval flicker ERGs in cataractous eyes is less affected by the pupil diameter. With our earlier study, it was assumed that the effect of cataracts on the RETeval flicker ERGs was due to the opacity of the crystalline lens, and the influence of the cataract would not be reduced or increased by mydriasis.
منابع مشابه
Effects of cataracts on flicker electroretinograms recorded with RETeval™ system: new mydriasis-free ERG device
BACKGROUND The purpose of this study was to evaluate the effects of cataracts on the flicker electroretinograms (ERGs) recorded with the RETeval™ system under mydriatic-free conditions. METHODS This was a retrospective study of 82 eyes of 60 patients with cataracts and 52 eyes of 38 patients who were pseudophakic. Flicker ERGs were recorded with the RETeval™ system (LKC Technologies, Gaithers...
متن کاملEffect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System.
PURPOSE We studied whether pupil size affects the flicker electroretinograms (ERGs) recorded by RETeval, a new mydriasis-free full-field flicker ERG system. METHODS We studied 10 healthy subjects. The RETeval manufacturer claims that the system delivers a constant flash retinal illuminance by adjusting the flash luminance to compensate for changes in the pupil size. Two experiments were perfo...
متن کاملFactors Affecting Mydriasis-Free Flicker ERGs Recorded With Real-Time Correction for Retinal Illuminance: Study of 150 Young Healthy Subjects.
Purpose A small, full-field flicker electroretinogram (ERG) recording system was recently developed to record flicker ERGs without mydriasis (RETeval). The device delivers a stimulus with constant retinal illuminance by adjusting the retinal luminance to compensate for changes in the pupillary area. The purpose of this study was to determine what factors affect the fundamental components of the...
متن کاملEvaluation of cone function by a handheld non-mydriatic flicker electroretinogram device
PURPOSE Full-field electroretinograms (ERGs) are used to evaluate retinal function in patients with various types of hereditary and acquired retinal diseases. However, ERG recordings require relatively invasive procedures, including pupillary dilation and the use of contact lens electrodes. Thus, it would be helpful to have a simpler and noninvasive screening method. The purpose of this study w...
متن کاملScreening for diabetic retinopathy using new mydriasis-free, full-field flicker ERG recording device
Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Therefore, it is important to detect DR accurately during mass screening. The purpose of this study was to determine whether a small, hand-held, mydriasis-free, full-field flicker electroretinographic (ERGs) device called RETeval can be used to screen for DR. To accomplish this, we recorded full-field flicker ER...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2018