Studies of the Synchronous Sensing Method in the Microfluidic Cell Impedance Detection

نویسندگان

  • Jie DAI
  • Kecheng YANG
چکیده

Microfluidic impedance sensors play a significant role in point-of-care applications, clinical tests and laboratory studies. Instead of the traditional signal process method with the envelope detector, filter banks and multistage amplifier, we have reported a new implement using synchronous sampling and orthogonal detecting. By studying the intensity and phase modulation in the cell impedance sensing progress, we have calculated the SNR of the new method compare with the raw data. Base on the physical model and the calculation, we have demonstrated a simulation result which shows a capability to detect the signal of 1um cell in a noisy environment. Copyright © 2014 IFSA Publishing, S. L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Impedance Spectroscopy for Detection of Cells in Suspensions Using Microfluidic Device with Integrated Microneedles

In this study, we introduce novel method of flow cytometry for cell detection based on impedance measurements. The state of the art method for impedance flow cytometry detection utilizes an embedded electrode in the microfluidic to perform measurement of electrical impedance of the presence of cells at the sensing area. Nonetheless, this method requires an expensive and complicated electrode fa...

متن کامل

Modified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation

In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...

متن کامل

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...

متن کامل

A Novel Integrated Dual Microneedle-Microfluidic Impedance Flow Cytometry for Cells Detection in Suspensions

Received Feb 18, 2017 Revised Apr 20, 2017 Accepted May 10, 2017 In this study, a new, simple and cost-effective impedance detection of yeast cell concentration by using a novel integrated dual microneedle-microfluidic impedance flow cytometry was introduced. The reported method for impedance flow cytometry detection utilizes embedded electrode and probe in the microfluidic device to perform me...

متن کامل

Impedance spectroscopy-based cell/particle position detection in microfluidic systems.

An impedance spectroscopy-based cell/particle position detection method in microfluidic systems is presented. A single pair of non-parallel surface microelectrodes was utilized to detect the transverse positions of particles/cells flowing in a microchannel without the need for a multi-electrode multi-channel impedance detection. This method can be a simple solution for high-throughput and low-c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014