Basic and Tailored RF Shimming in a Multi-transmit Whole Body MR System
نویسنده
چکیده
Wave propagation effects diminish the quality of MR images at main fields of 3T or above. Parallel RF transmission has the potential of compensating for these effects through RF shimming. RF shimming can be performed in two different ways. The basic way of RF shimming is to adjust the global amplitude and phase of the currents in each transmit element, aiming at a constant B1 in the region of interest. For 3D volume imaging, 3D RF shimming is facilitated using multiple frequencies for the different transmit elements. On the other hand, “tailored” RF shimming can be performed via multi-dimensional RF pulses designed to achieve a spatially constant excitation pattern. Using an MR system equipped with parallel RF channels, these multi-dimensional RF pulses can be accelerated via Transmit SENSE. The potential of both, basic and tailored RF shimming, can be enhanced significantly, if only a constant B1 amplitude is demanded, and an arbitrary spatial distribution of the resulting B1 phase is allowed. This is the case, if only magnitude images are of interest. However, this approach introduces a non-linear problem, requiring corresponding numerical techniques. Optimal results for basic RF shimming are obtained with transmit arrays owning preferably homogeneous sensitivity distributions of the individual elements. On the other hand, for tailored shimming, the transmit elements require orthogonal sensitivity distributions, which are easier to achieve with inhomogeneous sensitivity distributions. Thus, the transmit coil array cannot be optimized for both, basic and tailored RF shimming simultaneously, and a suitable compromise has to be found. This study compares the different RF shimming approaches using a whole-body, 8-channel Tx/Rx system at 3T. It shows, that basic RF shimming is able to remove B1 inhomogeneities to a high degree, both in phantoms and in vivo. Tailored RF shimming is able to achieve even higher levels of B1 homogeneity, which, however, might not be necessary for the majority of clinical applications.
منابع مشابه
MR Physics for Physicists / B1 Shimming and Parallel Transmission
METHODS: Currently, among other means, modifications of the applied RF pulses are investigated to cope with the mentioned B1 inhomogeneities. First, using a coil array for RF transmission, standard slice selective pulses can be transmitted with different weights in the different array elements (see, e.g., [2-4]). These weights, i.e., amplitude and phase of each element, are designed to yield a ...
متن کاملComparison of Whole Body Transmit Coil Configurations for RF Shimming at 3T
Introduction Whole body MRI at 3T may be impeded by B1 transmit field inhomogeneities caused by the dielectric shortening of the RF wavelength [1]. RF shimming techniques based on parallel transmission [2,3] can strongly improve the image quality in clinical whole body applications [4]. In this context, it is an important question, how the RF shimming performance depends on the chosen coil topo...
متن کاملAverage SAR Constrained Local RF Shimming
Introduction Achieving given homogeneity and SAR constraints in RF shimming process is an important problem in high field MRI. There are different studies in the literature which dealt with the optimization of these parameters by using non-convex optimization techniques. In a previous work whole body SAR constrained RF shimming problem was solved in order to achieve whole slice transmit homogen...
متن کاملSlab selective, regularized RF shimming
Introduction RF shimming is a well-known technique, where amplitudes and phases of a transmit RF coil array are optimized to obtain a homogeneous B1 profile, i.e., to compensate wave propagation effects at main fields of 3T or above (see, e.g., [1]). Among other anatomies, legs are particularly prone to wave propagation effects due to their bi-cylindrical geometry, resulting in significant sign...
متن کاملEvaluation of a Subject specific dual-transmit approach for improving B1 field homogeneity in cardiovascular magnetic resonance at 3T
BACKGROUND Radiofrequency (RF) shading artifacts degrade image quality while performing cardiovascular magnetic resonance (CMR) at higher field strengths. In this article, we sought to evaluate the effect of local RF (B1 field) shimming by using a dual-source-transmit RF system for cardiac cine imaging and to systematically evaluate the effect of subject body type on the B1 field with and witho...