The Norway elbow replacement. Design, technique and results after nine years.

نویسنده

  • F Risung
چکیده

The Norway elbow prosthesis is a non-constrained cemented total replacement. It depends on intact collateral ligaments for stability, and allows a full range of movement. The system includes several sizes of components, all freely interchangeable, and semi-constraint can be provided by a locking ring if damaged collateral ligaments make dislocation possible. The prosthesis has been used in more than 350 elbows in Norway and the detailed results for 118 elbows studied prospectively since 1987 are reported. It is inserted through a posterolateral triceps-splitting incision with minimal muscle disruption and bone resection, preserving the collateral ligaments. The results as regards pain relief and range of movement were comparable with those of other elbow prostheses, but there were fewer serious complications. At a mean follow-up of 4.3 years, the failure rate was 3.4%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Treatment of Tennis Elbow; Minimal Incision Technique

  Background: When non-operative treatment of tennis elbow fails; a surgical procedure can be performed to improve the associated symptoms. Different surgical techniques for treatment of lateral epicondylitis are prescribed. The purpose of this study was to evaluate the clinical outcomes of surgical treatment for tennis elbow based on small incision techniques.   Methods: This technique ...

متن کامل

Survivorship of the KUDO total elbow prosthesis--comparative study of cemented and uncemented ulnar components: 89 cases followed for an average of 6 years.

BACKGROUND The Kudo total elbow prosthesis (TEP) is a well-established implant with good mid-term results. The ulnar component can be placed with or without cement, and the humeral component is normally placed without cement. METHODS 89 Kudo type-5 total elbow prostheses were evaluated after a mean follow-up of 6 (1.7-11) years. The indication for joint replacement was rheumatoid arthritis in...

متن کامل

Revision interposition arthroplasty of the elbow.

Between 1996 and 2008, nine patients with severe post-traumatic arthritis underwent revision of a failed interposition arthroplasty of the elbow with a further interposition procedure using an allograft of tendo Achillis at a mean of 5.6 years (0.7 to 13.1) after the initial procedure. There were eight men and one woman with a mean age of 47 years (36 to 56). The mean follow-up was 4.7 years (2...

متن کامل

Total elbow replacement with the Souter-Strathclyde prosthesis in rheumatoid arthritis. Long-term follow-up.

We assessed the long-term results of 58 Souter-Strathclyde total elbow replacements in 49 patients with rheumatoid arthritis. The mean length of follow-up was 9.5 years (0.7 to 16.7). The mean pre-operative Mayo Elbow Performance Score was 30 (15 to 80) and at final follow-up was 82 (60 to 95). A total of 13 elbows (22.4%) were revised, ten (17.2%) for aseptic loosening, one (1.7%) for instabil...

متن کامل

Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.

BACKGROUND Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. METHODS This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 79 3  شماره 

صفحات  -

تاریخ انتشار 1997