Randomized, masked, in vitro comparison of three commercially available tear film osmometers
نویسندگان
چکیده
PURPOSE The purpose of this study was to compare the precision and accuracy of commercially available tear film osmometers. METHODS Contrived tear solution target values representing the physiological range of tear osmolarity (normal eyes 297 mOsm/L, moderately dry eyes 342 mOsm/L, and severe dry eyes 383 mOsm/L) were constructed using a mix of mono- and divalent electrolytes, metabolites, serum albumin, and pH balanced to 7.4. Solution values were randomized and masked from the investigators during testing. Osmometers (Wescor 5520 Vapro Pressure Osmometer: device A, TearLab Osmolarity System: device B, and i-Med Pharma i-Pen: device C) were calibrated according to manufacturer instructions. Each level was tested 64× on each osmometer across two sites. Accuracy was reported as a correlation coefficient against expected linear dilutions, precision was calculated as percent coefficient of variation. RESULTS Device A reported a correlation with known solutions of r2=0.98, with averages of 305.6±4.0, 352.2±5.5, and 389.8±4.0 mOsm/L, and coefficient of variations (CVs) of 1.3%, 1.6%, and 1.0%, respectively. Device B reported an r2=0.96, with averages of 300.6±3.7, 341.4±7.9, and 376.8±5.1 mOsm/L, and CVs of 1.2%, 2.3%, and 1.4%, respectively. Device C reported an r2=0.03, with averages of 336.4±21.5, 342.0±20.7, and 345.7±22.0 mOsm/L, and CVs of 6.4%, 6.1%, and 6.4%, respectively. CONCLUSION In this randomized, masked, in vitro study, device A and device B had significantly better accuracy and precision in measuring osmolarity of contrived tear solutions of known target values compared to device C. Device C showed insufficient performance to accurately and precisely delineate osmolarity levels in the physiological range. Furthermore, in vivo studies would be required to compare performance in human subjects.
منابع مشابه
Randomized comparison of in vivo performance of two point-of-care tear film osmometers
PURPOSE To compare the in vivo precision of two commercially available point-of-care osmometers among normal subjects with no dry eye disease. METHODS Twenty healthy adults with healthy ocular surfaces were evaluated by licensed eye care practitioners. All subjects had low Ocular Surface Disease Index score (<5), normal tear breakup time (>10 seconds), and no evidence of corneal fluorescein s...
متن کاملIn Vitro Comparison of Soybean Lecithin Based-Extender with Commercially Available Extender for Ram Semen Cryopreservation
Background Egg yolk is the main cryoprotectant agent in semen freezing extenders which is used in order to protect spermatozoa against cold shock. However elimination of animal bioproducts from the cryopreservation protocol is becoming mandatory. Therefore the aim of this study is to compare a previously studied homemade soya bean lecithin based extender with a commercially available extender f...
متن کاملA randomized double-masked study of 0.05% cyclosporine ophthalmic emulsion in the treatment of meibomian gland dysfunction.
PURPOSE To compare the efficacy of topical cyclosporine [0.05% cyclosporine A (CsA)] and preservative-free artificial tears in the treatment of meibomian gland dysfunction (MGD). METHODS A 3-month prospective, randomized, double-masked, parallel-group controlled trial enrolled 70 patients with symptomatic MGD and unstable tear film [tear breakup time (TBUT) <8 seconds]. Patients were randomiz...
متن کاملEffects of mitomycin-C on tear film, corneal biomechanics, and surface irregularity in mild to moderate myopic surface ablation: preliminary results.
PURPOSE To assess the effect of mitomycin-C (MMC) on the tear film, corneal biomechanics, and surface irregularity in surface ablation (photorefractive keratectomy [PRK]) for low to moderate myopia. SETTING Refractive Surgery Unit, Farabi Eye Hospital, Tehran, Iran. DESIGN Double-masked randomized clinical trial. METHODS In patients with spherical equivalent myopia of -0.75 to -3.87 diopt...
متن کاملA Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.
Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and ...
متن کامل