Direct imaging of bileaflet mechanical valve behavior in the tricuspid position.

نویسندگان

  • Kazuyuki Ikeda
  • Yukio Okazaki
  • Kojirou Furukawa
  • Satoshi Ohtsubo
  • Junji Yunoki
  • Masafumi Natsuaki
  • Tsuyoshi Itoh
چکیده

OBJECTIVE The optimal orientation of a bileaflet mechanical valve for tricuspid valve replacement (TVR) has not yet been determined. The aim of this study was to use fiberoptic cardioscopy to evaluate the effect of orientation of a mechanical valve implanted in the tricuspid position on bileaflet mechanical valve behavior. METHODS Twelve pigs (50-59 kg) underwent TVR with a St. Jude Mechanical Heart Valve (25 mm standard cuff model) after cardioplegic arrest. The mechanical valve was implanted horizontally in six pigs (Group H), and vertically in another six pigs (Group V). The heart was perfused with pellucid Krebs-Henseleit solution in situ and the mechanical valve behavior was observed with a fiberoptic endoscope during different heart rates (HRs) induced by ventricular pacing (60, 90, 120, 150 min(-1)). All images were recorded on a high-speed video system every 4 ms. The closing time lag (CTL) between the valve leaflets was calculated and compared between the two groups. RESULTS In Group H, the lower valve leaflet tended to open incompletely and close earlier than the upper leaflet. The calculated CTL was 303+/-60 ms, 65+/-48 ms, 40+/-9 ms, and 40+/-26 ms at pacing HRs of 60, 90, 120, and 150 min(-1), respectively. In contrast to Group H, there was little difference in CTL between the right and left leaflets in Group V. The calculated CTL was 9+/-12 ms, 11+/-10 ms, 1+/-3 ms, and 6+/-7 ms at pacing HRs of 60, 90, 120, and 150 min(-1), respectively. There were significant differences in CLT between the two groups at each ventricular pacing rate (P < 0.01). CONCLUSIONS Orientation of an implanted bileaflet valve in the tricuspid position significantly influenced leaflet motion. In a horizontal orientation, the lower valve leaflet opened incompletely and closed earlier than the upper leaflet. These results suggest that the gravity might affect leaflet motion and that bileaflet mechanical valves should be implanted vertically in TVR to prevent abnormal leaflet motion and thrombus formation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Bileaflet Mechanical Mitral Valve Rotational Orientation on Left Ventricular Flow Conditions

We studied left ventricular flow patterns for a range of rotational orientations of a bileaflet mechanical heart valve (MHV) implanted in the mitral position of an elastic model of a beating left ventricle (LV). The valve was rotated through 3 angular positions (0, 45, and 90 degrees) about the LV long axis. Ultrasound scans of the elastic LV were obtained in four apical 2-dimensional (2D) imag...

متن کامل

Balloon Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

A 73-year-old woman was admitted to our hospital for a scheduled percutaneous transcatheter balloon valvuloplasty of a stenotic tricuspid bioprosthesis. The patient had a history consistent with exertional dyspnea, abdominal distension, and edema of the lower extremities resistant to diuretic treatment over the previous few months. Forty-three years prior, she underwent aortic valve replacement...

متن کامل

Fabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering

Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Stuck mechanical tricuspid valve prosthesis: the valve that does not move.

A 44-year–old woman underwent mitral valve and tricuspid valve (TV) replacement 6 years earlier using an ATS bileaflet tilting disc prostheses (ATS Medical Inc., Minneapolis, MN) for combined valvular stenosis and regurgitation because of rheumatic heart disease. On a routine clinic visit, the patient reported progressive fatigue and pedal edema over the previous few weeks. On physical examinat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2006