Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance.

نویسندگان

  • Nina Ajmone Marsan
  • Jos J M Westenberg
  • Claudia Ypenburg
  • Victoria Delgado
  • Rutger J van Bommel
  • Stijntje D Roes
  • Gaetano Nucifora
  • Rob J van der Geest
  • Albert de Roos
  • Johan C Reiber
  • Martin J Schalij
  • Jeroen J Bax
چکیده

OBJECTIVES The aim of this study was to evaluate feasibility and accuracy of real-time 3-dimensional (3D) echocardiography for quantification of mitral regurgitation (MR), in a head-to-head comparison with velocity-encoded cardiac magnetic resonance (VE-CMR). BACKGROUND Accurate grading of MR severity is crucial for appropriate patient management but remains challenging. VE-CMR with 3D three-directional acquisition has been recently proposed as the reference method. METHODS A total of 64 patients with functional MR were included. A VE-CMR acquisition was applied to quantify mitral regurgitant volume (Rvol). Color Doppler 3D echocardiography was applied for direct measurement, in "en face" view, of mitral effective regurgitant orifice area (EROA); Rvol was subsequently calculated as EROA multiplied by the velocity-time integral of the regurgitant jet on the continuous-wave Doppler. To assess the relative potential error of the conventional approach, color Doppler 2-dimensional (2D) echocardiography was performed: vena contracta width was measured in the 4-chamber view and EROA calculated as circular (EROA-4CH); EROA was also calculated as elliptical (EROA-elliptical), measuring vena contracta also in the 2-chamber view. From these 2D measurements of EROA, the Rvols were also calculated. RESULTS The EROA measured by 3D echocardiography was significantly higher than EROA-4CH (p < 0.001) and EROA-elliptical (p < 0.001), with a significant bias between these measurements (0.10 cm(2) and 0.06 cm(2), respectively). Rvol measured by 3D echocardiography showed excellent correlation with Rvol measured by CMR (r = 0.94), without a significant difference between these techniques (mean difference = -0.08 ml/beat). Conversely, 2D echocardiographic approach from the 4-chamber view significantly underestimated Rvol (p = 0.006) as compared with CMR (mean difference = 2.9 ml/beat). The 2D elliptical approach demonstrated a better agreement with CMR (mean difference = -1.6 ml/beat, p = 0.04). CONCLUSIONS Quantification of EROA and Rvol of functional MR with 3D echocardiography is feasible and accurate as compared with VE-CMR; the currently recommended 2D echocardiographic approach significantly underestimates both EROA and Rvol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.

BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...

متن کامل

Automated Quantification of Mitral Regurgitation by Three Dimensional Real Time Full Volume Color Doppler Transthoracic Echocardiography: A Validation with Cardiac Magnetic Resonance Imaging and Comparison with Two Dimensional Quantitative Methods

BACKGROUND Accurate assessment of mitral regurgitation (MR) severity is crucial for clinical decision-making and optimizing patient outcomes. Recent advances in real-time three dimensional (3D) echocardiography provide the option of real-time full volume color Doppler echocardiography (FVCD) measurements. This makes it practical to quantify MR by subtracting aortic stroke volume from the volume...

متن کامل

Quantitative assessment of mitral regurgitation: comparison between three-dimensional transesophageal echocardiography and magnetic resonance imaging.

BACKGROUND quantification of mitral regurgitation severity with 2-dimensional (2D) imaging techniques remains challenging. The present study compared the accuracy of 2D transesophageal echocardiography (TEE) and 3-dimensional (3D) TEE for quantification of mitral regurgitation, using MRI as the reference method. METHODS AND RESULTS two-dimensional and 3D TEE and cardiac MRI were performed in ...

متن کامل

Multiplane two-dimensional versus real time three-dimensional transesophageal echocardiography in ischemic mitral regurgitation.

OBJECTIVES Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a pros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 2 11  شماره 

صفحات  -

تاریخ انتشار 2009