Improvement on detectability of early ischemic changes for acute stroke using nonenhanced computed tomography: effect of matrix size.
نویسندگان
چکیده
PURPOSE It has recently been reported that intravenous recombinant tissue plasminogen activator improves the clinical outcome after acute stroke. Computed tomography (CT) is the standard imaging method used to determine the indication for thrombolysis. However, detection of early ischemic change often results in an increase in local radiation exposure. Therefore, the effects of decreased matrix size and use of a noise reduction filter were evaluated. MATERIALS AND METHODS The low contrast resolution was compared for different matrix sizes and imaging filters using a contrast-detail phantom. In addition, early ischemic change in clinical images with matrix sizes of 256×256 and 128×128 processed using three imaging filters (Gaussian, smoothing, and unsharp mask) from 11 patients within 3h of stroke onset was evaluated by seven radiologists in a blind manner. RESULTS The use of images with a matrix size of 256×256 and processed with the Gaussian filter increased the detection of early signs of acute stroke. CONCLUSIONS This study was performed to determine whether the converted matrix size and use of imaging filters could improve the detectability of early ischemic change on CT images in acute stroke. To reduce the dose of radiation exposure for patients, it was effective to use an optimal noise reduction filter and reasonable matrix size. In particular, changing the matrix size to 256×256 was the most effective for detection of early ischemic change in examinations using clinical images.
منابع مشابه
Reliability of Persian Early Computed Tomography Score in Patients with Brain Infarction
Background: The one-third middle cerebral artery (1/3 MCA) method and Alberta Stroke Program Early Computed Tomography Score (ASPECTS) were used to detect significant early ischemic changes on brain computed tomography (CT) of patients with acute stroke. We designed the Persian Early CT Score (PECTS) and compared it with the above systems. Methods: The tomograms were chosen from the stroke data...
متن کاملImprovement of detection of hypoattenuation in acute ischemic stroke in unenhanced computed tomography using an adaptive smoothing filter.
BACKGROUND Much attention has been directed toward identifying early signs of cerebral ischemia on computed tomography (CT) images. Hypoattenuation of ischemic brain parenchyma has been found to be the most frequent early sign. PURPOSE To evaluate the effect of a previously proposed adaptive smoothing filter for improving detection of parenchymal hypoattenuation of acute ischemic stroke on un...
متن کاملAcute brain infarct: detection and delineation with CT angiographic source images versus nonenhanced CT scans.
PURPOSE To retrospectively compare sensitivity and specificity of admission nonenhanced computed tomographic (CT) scans with those of CT angiographic source images in detection of early ischemic changes in middle cerebral artery (MCA) stroke and to retrospectively compare admission nonenhanced CT scans with CT angiographic source images in delineation of final infarct extent, with follow-up ima...
متن کاملThe Effect of Intravenous Magnesium Sulfate in Improvement of Acute Ischemic Stroke Induced Disability: A Randomized Double Blinded Clinical Trial
Background: Stroke is the third main cause of death and chronic disabilities in adults, which requires finding neuroprotective drugs to reduce its mortality and morbidity. Objectives: To determine the efficacy of magnesium sulfate as an adjunctive neuroprotective agent in patients with stroke. Materials & Methods: This randomized double-blind clinical trial recruited 120 patients with acute ...
متن کاملImproved early stroke detection: Wavelet-based perception enhancement of computerized tomography exams
Nonenhanced computerized tomography (CT) exams were used to detect acute stroke by notification of hypodense area. Infarction perception improvement by data denoising and local contrast enhancement in multi-scale domain was proposed. The wavelet-based image processing method enhanced the subtlest signs of hypodensity, which were often invisible in standard CT scan review. Thus improved detectio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of radiology
دوره 76 2 شماره
صفحات -
تاریخ انتشار 2010