Robotic Manipulation of Ophthalmic Lenses Assisted by a Dedicated Vision System

نویسندگان

  • Xavier Fernández
  • Josep Amat
چکیده

A robotic system developed to manipulate ophthalmic lenses during the edging process is presented. The robot is assisted by a machine vision system to accurately determine the position and orientation of the lens optical center and axis, through the localization of two small fiducial marks on the lens surface. The optimal design of the j2ducial marks is investigated in order to minimize their size. It is shown that a regular diamond is the most detectable shape at minimum sizes. Three diferent camera placement strategies are discussed, taking into account accuracy constraints and calibration requirements; the chosen solution uses a camera attached to the robot end-effector. The robotic system proves to be advantageous with respect to the manual process, substantially improving the final accuracy while maintaining or even reducing the cycle time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward the Art of Robotic-assisted Vitreoretinal Surgery

New technological progress in robotics has brought many beneficial clinical applications. Currently, computer integrated robotic surgery has gained clinical acceptance for several surgical procedures. Robotically assisted eye surgery is envisaged as a promising solution to overcome the shortcomings inherent to conventional surgical procedures as in vitreoretinal surgeries. Robotics by its high ...

متن کامل

Self-optimised vision correction with adaptive spectacle lenses in developing countries.

It is estimated by the World Health Organization that about 1 billion people in the developing world would benefit immediately from distance vision and near vision correction if it were available to them. Here we address this problem and provide a solution by correcting vision in the field with adaptive liquid-filled variable focus lenses. We describe the details of the lens and present the res...

متن کامل

Aviation accidents and incidents associated with the use of ophthalmic devices by civilian airmen.

INTRODUCTION Approximately 54% of civilian pilots rely on ophthalmic lenses to correct defective vision in order to maintain a valid airman medical certificate. This report reviews aviation accidents and incidents where the use or misuse of ophthalmic devices was considered to have been a contributing factor in the mishap. METHODS The NTSB's Aviation Accident/Incident Database and the FAA's I...

متن کامل

Modified point diffraction interferometer for inspection and evaluation of ophthalmic components.

We demonstrate that a modified point diffraction interferometer can be used to measure the power distribution of different kinds of ophthalmic lenses such as spectacles, rigid and soft contact lenses, progressive lenses, etc. The relationship between the shape of the fringes and the power characteristics of the component being tested is simple and makes the design a very convenient and robust t...

متن کامل

Grasp analysis of a four-fingered robotic hand based on Matlab simmechanics

The structure of the human hand is a complex design comprising of various bones, joints, tendons, and muscles functioning together in order to produce the desired motion. It becomes a challenging task to develop a robotic hand replicating the capabilities of the human hand. In this paper, the analysis of the four-fingered robotic hand is carried out where the tendon wires and a spring return me...