Binocular visual function in patients with Boston type I keratoprostheses.
نویسندگان
چکیده
PURPOSE To report the postoperative binocular function of patients with Boston type I keratoprostheses implantation for unilateral visual impairment. METHODS Seventeen patients who underwent implantation of a Boston type I keratoprosthesis and had a best-corrected visual acuity better than 20/50 in the contralateral eye before surgery were evaluated. All subjects prospectively underwent sensory testing of binocular function including Bagolini lenses, Worth-4-dot test, stereoacuity at distance and near, and double Maddox rods. In addition, an assessment of ocular rotations and alignment was performed on each subject. RESULTS Twenty patients with best-corrected visual acuity better than 20/50 in the contralateral eye at the time of keratoprothesis surgery were identified. Seventeen of the 20 patients underwent binocular visual testing, with 16 of 17 (94%) demonstrating binocular function. Second-degree fusion at near was demonstrated via the Worth-4-dot test in 13 of 17 (76%) patients. Third-degree fusion at near was demonstrated in 7 of 17 (41%) patients. Patients with better postoperative sensory binocular function tended to be of younger age (P = 0.05) and have better postoperative visual acuity (P = 0.006). Five patients were found to have some degree of ocular misalignment. Overall, patients with strabismus had worse binocularity (P = 0.04). CONCLUSIONS Implantation of the Boston type I keratoprosthesis in patients with good preoperative visual acuity in the fellow eye is associated with useful binocular function in greater than 90% of patients.
منابع مشابه
Postoperative posterior segment complications in eyes treated with the Boston type I keratoprosthesis.
PURPOSE To describe the incidence, timing, visual significance, and management of posterior segment complications after Boston type I keratoprosthesis implantation. METHODS A retrospective chart review was conducted of all consecutive Boston type I keratoprostheses implanted by a single surgeon at a single institution over a 6-year period. Preoperative demographics, postoperative complication...
متن کاملEffect of Rehabilitation Interventions on Sensation, Function, and Pain of the Patients With Carpal Tunnel Release
Objectives: Carpal Tunnel Syndrome (CTS) is now the most common type of nerve compression neuropathies constituting about (90%) of the neuropathic disorders. To attain the optimal recovery following the operation, a rehabilitation intervention is urgent. This study aims at investigating the efficacy of short and long term rehabilitation interventions following Carpal Tunnel Release (CTR) on mot...
متن کاملResults with the Boston Type I keratoprosthesis after Acanthamoeba keratitis
Purpose To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. Observations Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I...
متن کاملInternational Outcomes of the Boston Type I Keratoprosthesis in Stevens-Johnson Syndrome.
PURPOSE To determine the factors influencing outcomes of Boston type I keratoprosthesis implantation in Stevens-Johnson syndrome (SJS) and to compare the results with those of individuals without SJS. METHODS This is a multicenter, retrospective, comparative consecutive case series of patients undergoing keratoprosthesis implantation in Los Angeles, Kolkata, and Manila. Statistical analysis w...
متن کاملتاثیر هم افزایی دوچشمی بر مولفه های موج پتانسیل برانگیخته بینایی
Background : To determine the effect of binocular summation on the time domain transient VEP wave's components. Methods : The monocular and binocular transient visual evoked potentials of 21 normally vision volunteers 18 to 24 years (mean ± SD, 20.7 ± 1.9) during a reversing checkerboard stimulus with spatiotemporal frequency of 2.18-4 cpd-Hz were recorded. The amplitude and latency of N75,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cornea
دوره 29 12 شماره
صفحات -
تاریخ انتشار 2010