Quantifying the regional load-bearing ability of trans-tibial stumps.

نویسندگان

  • Ming Zhang
  • Winson C C Lee
چکیده

This paper reports findings of experiments aiming to (1) compare the load tolerant ability over different regions of stumps of lower limb amputees, (2) study the effect of walking on the load tolerant ability, and (3) examine the distal-end weight-bearing ability supported by different interface materials. The method was to apply increasing load to the stump up to the pain level through a force transducer or a digital scale, considering the effect of regional difference, walking, and interface materials. The results show that the patellar tendon and the distal end of the fibula were the best and worst load-tolerant region, respectively. Walking with prostheses tended to increase the load-tolerant ability, which is thought to be due to the massage-like effect of the socket. Different interface materials did not significantly alter the distal-end weight-bearing ability. However, there was a great difference in the distal-end weight-bearing ability among different subjects.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stump length as related to atrophy and strength of the thigh muscles in trans-tibial amputees.

Stump length and the thigh muscles strength of the amputated limb are among the major factors influencing outcome of prosthetic rehabilitation of trans-tibial amputees. In the present study the authors evaluated and compared the strength of quadriceps and hamstrings muscles of both limbs in trans-tibial amputees, as measured by means of an electrical dynamometer. The obtained results showed tha...

متن کامل

Seated-popliteal weight bearing prosthesis for a bilateral amputee.

Bilateral lower limb amputees suffer from a lack of stability when seated without prostheses due to lack of ground reaction forces through the stumps. In patients for whom ambulation is not a realistic goal, the seated-popliteal weight bearing prosthesis provides a solution for stability when seated in a wheelchair, without the problem of tibial pressure experienced with patellar-tendon-bearing...

متن کامل

A new trim line concept for trans-tibial amputation prosthetic sockets.

Introduction Proximal trim lines for trans-tibial prosthetic sockets have traditionally been trimmed according to the mode of suspension to the limb. The supracondylar suspension, which retains the prosthetic socket to the limb by gripping above the femoral condyles, has a more proximal trim line compared to the more distal trim line used for a suspension with a patellar-tendon-bearing strap or...

متن کامل

A comparison of trans-tibial amputee suction and vacuum socket conditions.

Daily volume loss of the stump leads to a poor fit of the prosthetic socket. A method of preventing this volume loss and maintaining a good fit was developed. A vacuum (-78 kPa) was drawn on the expulsion port of a total surface-bearing suction socket to hold the liner tightly against the socket. Stump volume of 10 trans-tibial amputees was measured prior to and immediately after a 30 minute wa...

متن کامل

Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee.

Most trans-tibial amputation (TTA) patients use a prosthesis to retain upright mobility capabilities. Unfortunately, interaction between the residual limb and the prosthetic socket causes elevated internal strains and stresses in the muscle and fat tissues in the residual limb, which may lead to deep tissue injury (DTI) and other complications. Presently, there is paucity of information on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2006