Method for expanding the uniformly shielded area in a short-length open-ended cylindrical magnetic shield

نویسندگان

  • G. W. Jewell
  • K. Oshita
  • I. Sasada
  • H. Naka
چکیده

A compensation method is proposed by which the uniformly shielded area of the axial magnetic field in a relatively short, open-structure axial magnetic shield can be extended. An open-ended cylindrical magnetic shield of 120 cm in length, 52 cm inner diameter, and a ;0.5 mm total thickness of the shielding material is used to demonstrate the idea. The shield axis is oriented along the horizontal component ~;320 mG! of the Earth’s magnetic field. A simple way to increase the axial shielding factor is to use a pair of compensating coaxial ring coils set at both open ends of the shield. This increases, however, the radial gradient of the shielded field since the axial compensation field is stronger towards the shield axis. In order to decrease the radial gradient, an additional ring coil is wound around the middle part of the outer surface of the shield. The compensating field generated by this central ring coil is stronger towards the inner surface of the shield, and it helps, therefore, to unify the axial resultant field over a wider area inside the shield. The axial shielding factor obtained with this compensation according to the proposed method is 128, in contrast to only 16.4 obtained with compensation by a set of two ring coils. The field gradients observed are 1.2 mG/cm along the length direction and 2.7 mG/cm along the radial direction, in contrast to the 14 mG/cm axial and 78 mG/cm radial gradients obtained with compensation by a set of two ring coils. © 1999 American Institute of Physics. @S0021-8979~99!55508-4#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effects of Cut-Out Shield on High-Energy Electron Fields Using MAGIC Normoxic Polymer Gel

Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...

متن کامل

Effect of magnetic anisotropy on magnetic shaking

The effect of magnetic shaking on both the transverse and axial shielding factors ~TSF and ASF! is investigated using open-ended cylindrical shields made of Metglas 2705M amorphous ribbons. Shaking enhancement is found to be strongly dependent on the orientation of the magnetic anisotropy of the shielding material, that is, the anisotropy axis should be aligned along the corresponding shielding...

متن کامل

Discrete Design Method of a Transverse Gradient Coil for Magnetic Resonance Imaging

S. Shvartsman, G. DeMeester, M. Morich Philips Medical Systems, Cleveland, Ohio, United States Introduction In this work we describe a discrete gradient coil design method that does not include some of the essential steps of continuous current based minimum energy design methods. The key concept is that all characteristics of a transverse gradient, such as coil inductance, spatial distribution ...

متن کامل

Effect of Material and Wall Thickness Buildup Caps on the Head ScatterFactor Measurements in Irregular Fields Shielded by Cerrobend

Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. <str...

متن کامل

Software for Design NMR Probes Using the Shielded Split Ring and the Shielded Symmetrical Band Resonators

This article presents a software (NMR PROBES) for design NMR probes using closed-forms formulas of the primary and secondary parameters of the shielded split ring [1] and the shielded symmetrical band resonators [2]. These formulas are based on rigorous analysis by finite element method (FEM) [3], [4], method of moment (MoM) [5] and curves fitting techniques. The presented software permits the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999