A prospective comparison of duplex sonography vs angiography of the vertebral arteries.

نویسندگان

  • P C Davis
  • B Nilsen
  • I F Braun
  • J C Hoffman
چکیده

A prospective blind comparison was completed between duplex sonography and angiography of the vertebral arteries. Thirty-two vertebral arteries were studied for direction of flow, degree of origin plaque or stenosis, Doppler characteristics, and vessel size. The vertebral arteries were reliably identified by imaging their course from the subclavian artery into the transverse foramina and by identifying a Doppler signal similar in waveform to the internal carotid artery. With Doppler, a 90% accuracy was obtained for direction of blood flow. Nonvisualization of origins was primarily due to vessel depth and/or tortuosity. In 12 vessel origins that were well seen with both techniques, angiography and sonography agreed in two-thirds of the cases. In four cases, origin plaque was underestimated with duplex imaging. Interestingly, no Doppler frequency or velocity elevation was identified distal to significant stenoses. One false-positive diagnosis of occlusion occurred with sonography, in which a 99% origin stenosis resulted in no detectable Doppler signal. By comparing sonography with angiography, sonography was shown to be 80% accurate in determining vertebral artery size. Our preliminary results indicate that duplex scanning is a reasonably accurate screening technique for size, patency, and direction of blood flow in the vertebral arteries. Duplex evaluation of the vertebral artery origin was limited by vessel depth, tortuosity, and calcifications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclavian steal syndrome detected with duplex pulsed Doppler sonography.

In the evaluation of the extracranial carotid circulation for occlusive disease, duplex sonography was used routinely to determine the direction of flow in the vertebral arteries. Of 600 patients examined, 15 were found to have reversed flow in a vertebral artery-the subclavian steal syndrome. This was confirmed in the seven patients who underwent angiography. Duplex sonography was found to be ...

متن کامل

Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral...

متن کامل

Captopril renography and duplex Doppler sonography in the diagnosis of renovascular hypertension.

BACKGROUND The purpose of this prospective study was to determine the clinical usefulness of captopril renal scintigraphy and duplex Doppler sonography in detecting haemodynamically significant renal artery stenosis (> or = 60%) and predicting cure or improvement of hypertension following revascularisation. METHODS Twenty-eight patients with moderate or high index of clinical suspicion of ren...

متن کامل

The contribution of ultrasound of the craniocervical arteries to the diagnosis of giant cell arteritis

AIM Evaluation of the diagnostic contribution of color duplex sonography of the temporal, carotid and vertebral arteries and doppler sonography of the periorbital arteries in patients with and without giant cell arteries (GCA) particularly to distinguish between arteritic and nonarteritic neuro-ophthalmological vascular complications (NOC). METHODS In a prospective study ultrasonographic find...

متن کامل

Vertebral Arteries in Healthy Adults

Background and Purpose To noninvasively estimate cerebral blood flow volume, a prospective study of color duplex sonography of the common, external, and internal carotid arteries and vertebral arteries of healthy adults was done. Cerebral blood flow was calculated with the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Methods Using a 7.0-MHz linear transducer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 1986