Secondhand aerosol exposure during mechanical ventilation with and without expiratory filters: An in-vitro study

نویسندگان

  • Arzu Ari
  • James B. Fink
  • Susan P. Pilbeam
  • James B Fink
  • Sue Pilbeam
چکیده

Secondhand aerosol exposure during mechanical ventilation with and without expiratory filters: An in-vitro study. Abstract Background: Concerns have been expressed about risk of exposure to exhaled aerosols to ICU personnel. AIM: To quantify amount of aerosol collected at the exhaust outlet of mechanical ventilators operated with and without filters in the expiratory limb. Methods: Two categories of ventilators were tested: (1) Ventilators without Proprietary Filters: Servo-i (Maquet) and Galileo (Hamilton) and (2) Ventilator with proprietary filters: PB 840 (Covidien). Each ventilator was attached to a simple test lung and operated with VT 500 ml, RR 20 bpm, PIF 50 L/min, PEEP 5 cmH2O. Four separate doses of albuterol (2.5 mg/3mL) were administered via jet nebuliser (eValueMed, Tri-anim) placed at the " Y ". In Experiment A, a filter (Respirgard 303) was placed at the exhaust port. In Experiment B, two filters were attached to the ventilators without proprietary filters: (1) at the end of expiratory limb and (2) at the exhaust outlet. Drug was eluted from filters and measured using spectrophotometry. Results: Drug deposited at the exhaust port without expiratory filtering was >160 fold higher than with expiratory filtering. The collecting filter used in this study was less efficient than the proprietary filter designed for use with the ventilator. Regardless of type of filter used, placement of filter in the expiratory limb reduced secondhand aerosol exposure significantly. Conclusion: Risk of secondhand exposure to exhaled aerosol can account for >45% of nominal dose as well as droplet nuclei produced by patients. Using expiratory filters decreases risk of exposure to aerosol released to the atmosphere during mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

BACKGROUND Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. OBJECTIVES To evaluate the influence of nebulization and activ...

متن کامل

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

Pressurized Metered-Dose Inhalers Versus Nebulizers in the Treatment of Mechanically Ventilated Subjects With Artificial Airways: An In Vitro Study.

BACKGROUND The primary focus of previous aerosol research during mechanical ventilation was the endotracheal tube (ETT). Consequently, there are limited data in the literature on the delivery of inhaled medications administered with different aerosol devices in mechanically ventilated patients with a tracheostomy tube (TT). The purpose of this study was to quantify and compare the efficiency of...

متن کامل

Reconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.

We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p < 0.01). In 10 mechanically ven...

متن کامل

Optimized aerosol delivery to a mechanically ventilated rodent.

BACKGROUND Aerosol delivery through an endotracheal tube during mechanical ventilation of small animals, simulating neonates and small infants, has shown to be influenced by a variety of factors including aerosol generator type, droplet/particle size, ventilator circuitry and ventilation regime. A review of the literature indicates that reported aerosol deposition rates in rodents are quite low...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016