چکیده

PURPOSE/RELEVANCE Fibrosis and hence capsule formation around the glaucoma implants are the main reasons for glaucoma implant failure. To address these issues, we designed a microfluidic meshwork and tested its biocompatibility in a rabbit eye model. The amount of fibrosis elicited by the microfluidic meshwork was compared to the amount elicited by the plate of conventional glaucoma drainage device. METHODS Six eyes from 3 New Zealand albino rabbits were randomized to receive either the novel microfluidic meshwork or a plate of Ahmed glaucoma valve model PF7 (AGV PF7). The flexible microfluidic implant was made from negative photoresist SU-8 by using micro-fabrication techniques. The overall size of the meshwork was 7 mm × 7 mm with a grid period of 100 μm. Both implants were placed in the subtenon space at the supratemporal quadrant in a standard fashion. There was no communication between the implants and the anterior chamber via a tube. All animal eyes were examined for signs of infection and implant erosion on days 1, 3, 7, and 14 and then monthly. Exenterations were performed in which the entire orbital contents were removed at 3 months. Histology slides of the implant and the surrounding tissues were prepared and stained with hematoxylin-eosin. Thickness of the fibrous capsules beneath the implants were measured and compared with paired student's t-test between the two groups. RESULTS The gross histological sections showed that nearly no capsule formed around the microfluidic meshwork in contrast to the thick capsule formed around the plate of AGV PF7. Thickness of the fibrotic capsules beneath the AGV PF7 plate from the 3 rabbit eyes was 90μm, 82μm, and 95 μm, respectively. The thickness at the bottom of fibrotic capsules around the new microfluidic implant were 1μm, 2μm, and 1μm, respectively. The difference in thickness of capsule between the two groups was significant (P = 0.002). No complications were noticed in the 6 eyes, and both implants were tolerated well by all rabbits. CONCLUSION The microfluidic meshwork elicited minimal fibrosis and capsule formation after 3-months implantation in a rabbit model. This provides promising evidence to aid in future development of a new glaucoma drainage implant that will elicit minimal scar formation and provide better long-term surgical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery

Trabeculotomy (LOT) is performed to reduce the intraocular pressure in patients with glaucoma, both in children and adults. It relieves the resistance to aqueous flow by cleaving the trabecular meshwork and the inner walls of Schlemm's canal. Microhook ab interno LOT (µLOT), a novel minimally invasive glaucoma surgery, incises trabecular meshwork using small hooks that are inserted through corn...

متن کامل

Aqueous Humor Levels of Soluble Fas and Fas-ligand in Patients with Primary Open Angle and Pseudoex-foliation Glaucoma

Background: Glaucoma is one of the most common causes of blindness and is usually associated with elevated intraocular pressure. In patients with primary open angle glau-coma the number of trabecular meshwork cells is decreased. Death of the trabecular meshwork cells may be a result of apoptosis. Objective: To investigate the aqueous humor levels of soluble Fas (sFas) and Fas-Ligand (sFasL) in ...

متن کامل

An emerging treatment option for glaucoma: Rho kinase inhibitors

Rho kinase (ROCK) inhibitors are a novel potential class of glaucoma therapeutics with multiple compounds currently in Phase II and III US Food and Drug Administration trials in the United States. These selective agents work by relaxing the trabecular meshwork through inhibition of the actin cytoskeleton contractile tone of smooth muscle. This results in increased aqueous outflow directly throu...

متن کامل

Glaucoma surgery and aqueous outflow: how does nonpenetrating glaucoma surgery work?

B LEBS. SHALLOW CHAMBERS. Bleb leaks. Flat chambers. Dellen. Blebitis. No bleb. Late failure. Hypotony. Choroidal effusions. Maculopathy. Is there a better way? If the problem is in the meshwork, why do we cut a hole in the eye? Viscocanalostomy and deep sclerectomy are surgical procedures for glaucoma that have been designed to avoid some of the complications of conventional glaucoma surgery. ...

متن کامل

Preservative toxicity in glaucoma medication: clinical evaluation of benzalkonium chloride-free 0.5% timolol eye drops

Timolol (generic name) is a frequently used medication for the control of glaucoma. Benzalkonium chloride (BAK) is a commonly used preservative in ophthalmic solutions with a broad range of antimicrobial activity; however, this nonspecificity can result in toxicity. Adverse effects attributed to BAK, including conjunctival inflammation and fibrosis, tear film instability, corneal cytotoxicity, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017