Computed Tomography Imaging Strategies and Perspectives in Orbital Fractures

نویسندگان

  • Denise Takehana dos Santos
  • Jefferson Xavier Oliveira
  • Michael Walter Vannier
  • Marcelo Gusmão Paraíso Cavalcanti
چکیده

OBJECTIVE The objective of this study was to demonstrate the sensitivity and specificity of multislice computed tomography (CT) for diagnosis of orbital fractures following different protocols, using an independent workstation. MATERIALS AND METHODS CT images of 36 patients with maxillofacial fractures (symptomatic to orbit region) who were submitted to multislice CT scanning were analyzed, retrospectively. The images were interpreted based on 5 protocols, using an independent workstation: 1) axial (original images); 2) multiplanar reconstruction (MPR); 3) 3D images; 4) association of axial/MPR/3D images and 5) coronal images. The evaluated anatomical sites were divided according to the orbital walls: lateral (with or without zygomatic frontal process fracture); medial; superior (roof) and inferior (anterior, medial). The collected data were analyzed statistically using a validity test (Youden's J index; p<0.05). The clinical and/or surgical findings (medical records) were considered as the gold standard to corroborate the diagnosis of the anatomical localization of the orbital fracture. RESULTS 3D-CT scanning presented sensitivity of 78.9%, which was not superior to that of MPR (84.0%), axial/MPR/3D (90.5%) and coronal images (86.1%). On the other hand, the diagnostic value of axial images was considered limited for orbital fractures region, with sensitivity of 44.2%. CONCLUSIONS Except for the axial images, which presented a low sensitivity, all methods evaluated in this study showed high specificity and sensitivity for the diagnosis of orbital fractures according to the proposed methodology. This protocol can add valuable information to the diagnosis of fractures using the association of axial/MPR/3D with multislice CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

3-D computed tomography reconstruction: another tool to teach anatomy in the veterinary colleges

This letter underpins the use of three-dimensional computed tomography (3D-CT) reconstruction as an aid to teach veterinary anatomy. Cases were presented to students in order to observe normal and clinically abnormal patients. The images provided excellent details of relevant structures and could serve as a tool for teaching anatomy. Many sources describe different options to enhance anatomical...

متن کامل

Single Orbital Metastasis in Castration-Resistant Prostate Cancer

Introduction: Orbital metastasis of prostate cancer (PC) is very rare and even more unique in castration-resistant PC (CRPC). In this scenario, choline positron emission tomography/computed tomography (choline PET/CT) is the gold-standard restaging method of choice available in our setting, and new anti-androgens treatments show improvement in overall survival. Case presentation: We report the...

متن کامل

Single Orbital Metastasis in Castration-Resistant Prostate Cancer

Introduction: Orbital metastasis of prostate cancer (PC) is very rare and even more unique in castration-resistant PC (CRPC). In this scenario, choline positron emission tomography/computed tomography (choline PET/CT) is the gold-standard restaging method of choice available in our setting, and new anti-androgens treatments show improvement in overall survival. Case presentation: We report the...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2007