Use of titanium wire in cervical spine fixation as a means to reduce MR artifacts.
نویسندگان
چکیده
MR imaging of the cervical spine is valuable for assessing traumatic injuries to the spinal cord and bony ligamentous structures. MR is also useful for detecting such long-term complications of spinal cord injury as syrinx, arachnoid cyst, cord adhesion, and persistent mechanical impingement on the spinal cord or spinal nerve roots. Treatment of cervical spine injuries that are mechanically unstable entails fixation and fusion. However, previous attempts at our institution to obtain clinically useful MR images of the cervical region after posterior wire fixation have failed because of image artifacts arising from ferromagnetic stainless steel wires. Use of biocompatible titanium wire for fixation allowed undistorted imaging of the spinal cord and spinal canal adjacent to the surgical fixation in a cadaver and in eight patients.
منابع مشابه
Migration of titanium cable into spinal cord and spontaneous C2 and C3 fusion
INTRODUCTION Atlantoaxial instability is a common and serious injury of the upper cervical spine. Brooks' procedure is widely used to reconstruct the unstable atlantoaxial joint. The migration into spinal cord of titanium cable and spontaneous fusion between C2 and C3 has been little reported and the management of such a patient is difficult. We describe an unusual case of fatigue failure of po...
متن کاملDelayed Esophageal Pseudodiverticulum after Anterior Cervical Spine Fixation: Report of 2 Cases
Introduction: Although perforation of the esophagus, in the anterior cervical spine fixation, is well established, cases with delayed onset, especially cases that present pseudodiverticulum, are not common. In addition, management of the perforation in this situation is debated. Case Report: Delayed esophageal pseudodiverticulum was managed in two patients with a history of anterior spine fi...
متن کاملBLADE in sagittal T2-weighted MR imaging of the cervical spine.
BACKGROUND AND PURPOSE Image quality and diagnostic reliability of T2-weighted MR images of the cervical spine are often impaired by several kinds of artifacts, even in cooperative patients. The aim of this study was to evaluate if BLADE sequences might solve these problems in a routine patient collective. MATERIALS AND METHODS TSE and BLADE sequences were compared in 60 patients for T2-weigh...
متن کاملExpansive open-door laminoplasty with titanium miniplate versus sutures.
Expansive laminoplasty is an effective treatment for cervical myelopathy. Since the design of classic open-door laminoplasty with the use of suture, the procedure has been modified to reduce complications such as restenosis, axial symptoms, and segmental motor paralysis. Expansive open-door laminoplasty with the use of titanium miniplate is becoming popular. It is effective in expanding spinal ...
متن کاملA Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.
A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 9 6 شماره
صفحات -
تاریخ انتشار 1988