Monitoring Light Source for Cms Lead Tungstate Crystal Calorimeter at Lhc

نویسندگان

  • L. ZHANG
  • D. T. LIU
چکیده

Light monitoring will serve as an intercalibration for compact muon solenoid (CMS) lead tungstate crystals in situ at the large hadronic collider, which is crucial for maintaining crystal calorimeter’s subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO4 crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The CMS crystal calorimeter for the LHC

The CMS crystal calorimeter, comprising about 80,000 scintillating lead tungstate crystals read out by avalanche photodiodes (in the barrel) and vacuum phototriodes (in the endcap), is designed to give excellent energy resolution in the demanding LHC environment. It is now entering the construction phase. A status report on the project is presented, including recent results from test beam verif...

متن کامل

ECAL Front-End Monitoring in the CMS experiment

The CMS detector at LHC is equipped with a high precision lead tungstate crystal electromagnetic calorimeter (ECAL). The front-end boards and the photodetectors are monitored using a network of DCU (Detector Control Unit) chips located on the detector electronics. The DCU data are accessible through token rings controlled by an XDAQ based software component. Relevant parameters are transferred ...

متن کامل

The CMS ECAL project – Overview and status report

An overview is given of the Lead Tungstate (PbWO4) electromagnetic crystal calorimeter for the CMS detector at the Large Hadron Collider (LHC) at CERN in Geneva. This includes a description of the engineering design, the development of the calorimeter components, the read-out system and results obtained in particle beams. Presented at IEEE Nuclear Science Symposium, Toronto, Canada, November 19...

متن کامل

Measurements of PbWO4 crystals behaviour under irradiation

Lead Tungstate crystals for the CMS detector at LHC have to withstand severe levels of radiation. Presented here are measurement techniques and results on crystal behaviour under gamma irradiation from tests at ETH/PSI in conditions similar to what is expected during operation of the CMS electromagnetic calorimeter. Presented at International Workshop on Lead Tungstate crystals, Rome, Italy, Oc...

متن کامل

Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter

Further tests of lead tungstate crystal matrices made in high energy electron beams in 1996, using new crystals, new APDs and an improved test setup confirm that an energy resolution of better than 0.6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001