Implementation of an HIV-1 Triple-Target NAT Assay in the Routine Screening at Three German Red Cross Blood Centres.
نویسندگان
چکیده
BACKGROUND Blood product safety was significantly improved by the introduction of NAT testing in the late 1990s, resulting in a strong decrease of transfusion-transmitted infections (TTIs). Due to the occurrence of HIV-1 NAT test failures as a consequence of mismatch mutations in the amplicon regions of mono-target NAT assays, the Paul Ehrlich Institute mandated the implementation of multi-target NAT assays for HIV-1 in 2014. Commercial suppliers mostly developed dual-target NAT assays, with only one implementing a triple-target NAT assay. METHODS The HIV-1 triple-target NAT assay v3 (GFE Blut) was tested on mutated specimens and synthetic DNA bearing mutations that resulted in sample underquantification or false-negative test results. In addition, data from 2 years routine testing at three German Red Cross Blood centres were analysed. RESULTS The HIV-1 triple-target PCR could compensate for all mutations tested and could compensate the loss of one amplicon without a significant loss of sensitivity. Data from 2 years routine testing showed a solid performance. CONCLUSION The HIV-1 triple-target v3 assay (GFE Blut) can compensate mutations in target sequences better than a dual-target assay and is applicable to high-throughput screening, thus increasing blood product safety.
منابع مشابه
Human immunodeficiency virus, hepatitis C and hepatitis B infections among blood donors in Germany 2000-2002: risk of virus transmission and the impact of nucleic acid amplification testing.
Blood and plasma donations in Germany are collected by several institutions, namely the German Red Cross, community and hospital-based blood services, private blood centres, commercial plasma donation sites and transfusion services of the army. All blood donation centres are required to report quarterly data on infection markers to the Robert Koch Institute, thus providing current and accurate ...
متن کاملThree-Year Experience in NAT Screening of Blood Donors for Transfusion Transmitted Viruses in Croatia.
Background Croatia implemented individual donation (ID)-NAT testing of blood donors in 2013 for three viruses HBV, HCV, and HIV-1 as a mandatory test for all blood donors. This study assessed the impact of NAT screening 3 years after its implementation. Methods A total of 545,463 donations were collected and screened for HBV, HCV, and HIV-1 using the Procleix Ultrio Plus Assay. All initially ...
متن کاملComparison of Procleix Ultrio Elite and Procleix Ultrio NAT Assays for Screening of Transfusion Transmitted Infections among Blood Donors in India
Background. Introduction of nucleic acid testing (NAT) has helped in decreasing window period donations, resulting in increased safety of blood supplies. NAT combines the advantages of direct and highly sequence-specific detection of viral genomes. We analysed the performance of newer Procleix Ultrio Elite (PUE) and Procleix Ultrio assay (PUA) for the screening of the viral markers in our donor...
متن کاملNucleic Acid Amplification Testing: The New Infectious Disease Testing Method for Donor Blood.
Beginning in the spring of 1999, the American Red Cross and 16 member laboratories of the America’s Blood Centers began testing donor blood for the human immunodeficiency virus (HIV) type-1 and the hepatitis C virus with a new research testing method known as nucleic acid amplification testing (NAT). This testing is conducted under well-defined Investigational New Drug research protocols approv...
متن کاملMulticenter evaluation of individual donor nucleic acid testing (NAT) for simultaneous detection of human immunodeficiency virus -1 & hepatitis B & C viruses in Indian blood donors.
BACKGROUND & OBJECTIVE India has a high prevalence of HIV-1, hapatitis C and B virus (HCV and HBV) in the blood donors but has yet to implement nucleic acid testing (NAT) in blood screening. We undertook a multicentre evaluation of blood donor testing by NAT for simultaneous detection of HIV-1, HBV and HCV in a single tube and also to determine the feasibility of NAT implementation in India's l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie
دوره 43 3 شماره
صفحات -
تاریخ انتشار 2016