Influence of Microwave Sterilization on the Cutting Capacity of Carbide Burs

نویسندگان

  • Laiza Maria Grassi Fais
  • Lígia Antunes Pereira Pinelli
  • Gelson Luis Adabo
  • Regina Helena Barbosa Tavares da Silva
  • Caroline Canhizares Marcelo
  • Dalton Geraldo Guaglianoni
چکیده

OBJECTIVE This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. MATERIAL AND METHODS Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. RESULTS The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. CONCLUSION Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Different Sterilization Methods on the Uniformity of Diamond Dental Burs and the Change in the Cutting Edge of Carbide Burs by Electron Microscopy

Introduction: Dental burs are one of the most commonly used materials in dental offices and have, therefore, the highest risk of cross-contamination. Accordingly, sterilization of dental burs is highly recommended. Using the electron microscopy, this study aimed to evaluate the results of different sterilization methods on the uniformity of diamond dental burs and the change in the cutting edge...

متن کامل

Comparison of two ultrasonic cleaning units for deterioration of cutting edges and debris removal on dental burs.

The effects of two ultrasonic cleaning units on surface deterioration and cleaning effectiveness of dental burs were compared in this study. The units tested were the Dextrex Model L 503B (Dextrex Chemical Industries, Inc., Bowling Green, KY) industrial ultrasonic unit and a conventional dental ultrasonic unit L & R T-21 B (L & R Manufacturing Co., Kearny, NJ). SEM photomicrographs of the burs ...

متن کامل

Influence of type of bur and acid etching on dentin hydraulic conductance.

The aim of this study was to compare ex vivo filtration rate (hydraulic conductance) in human dentin discs mechanically treated with diamond and carbide burs of different grain size with or without acid etching. Method: 60 healthy third molars, recently extracted from patients aged 18-30 years, were cleaned, disinfected (0.1% thymol) and embedded in epoxy resin blocks. Dentin discs were obtaine...

متن کامل

Evaluation of chemical and biological consequences of soil sterilization methods

Sterilized soils are commonly used for the study of xenobiotic sorption and as an abiotic control in biodegradation experiments. They are also used for the chemical study of nitrogen and carbon cycle processes and the elimination of the biological factors. In this research the effects of different soil sterilization methods such as autoclaving, fumigating and exposure to ultraviolet and microwa...

متن کامل

Comparative efficiency testing 330 carbide dental burs utilizing Macor substrate.

Traditionally, it has been difficult to compare the clinical performance of carbide dental burs. The purpose of this laboratory study was to investigate the comparative cutting efficiency of number 330 dental burs from six manufacturers. These burs were tested utilizing custom-built equipment consisting of a frictionless air sled to which the Macor substrate was attached. The substrate was fed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2009