Mechanical Evaluation of Long Titanium Alloy Clip—Comparison of Cobalt Alloy Clip

نویسندگان

  • Tetsuyoshi HORIUCHI
  • Kiyoshi ITO
  • Kazuhiro HONGO
  • Masato SHIBUYA
چکیده

Long titanium aneurysm clips have recently been released. In the present study, comparative study of long titanium and cobalt alloy clips was performed. Two kinds of Sugita long clips (straight clips of 25- and 35-mm blade length) made of titanium and cobalt alloys were tested by measuring the closing force, the anti-scissoring torque, and the maximum opening width. There were some differences between the two materials. In the 25-mm blade length clip, closing force and maximum opening width of titanium alloy clip were greater than those of cobalt alloy clip. By contrast, the anti-scissoring torque of 35-mm blade length titanium clip was stronger than that of the cobalt. The long titanium clips would have equivalent endurance to long cobalt clip and are safe for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subtraction 3D CT angiography with the orbital synchronized helical scan technique for the evaluation of postoperative cerebral aneurysms treated with cobalt-alloy clips.

BACKGROUND AND PURPOSE CT angiography (CTA) has been used for the evaluation of intracranial aneurysms and recently has been applied to assess postoperative aneurysms treated with titanium-alloy clips. We investigated the clinical usefulness of subtraction CTA by using the orbital synchronized helical scan technique (OSHST) for evaluating intracranial aneurysms surgically treated with cobalt-al...

متن کامل

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

OBJECTIVE Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. METHODS Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the ang...

متن کامل

Evaluation of Flank Wear of Iron-rich Binder Carbide Cutting Tool in Turning of Titanium Alloy

Despite the fact that Titanium material has been considered as difficult to cut material, its usage has been increasing day by day in all engineering sectors; wherever criticality is encountered. Many studies are going on in view of increasing tool life at high cutting speed to improve productivity. In this study, attempt has been made to see the effect of iron as a partial substitution  along ...

متن کامل

Minimizing clip artifacts in multi CT angiography of clipped patients.

PURPOSE To optimize the multi CTA (MSCTA) protocol, the influence of pitch, kilovoltage peak (kVp), reconstruction algorithm, type, and orientation of the clip on clip-induced artifacts was investigated in a phantom study. Also, the influence of kVp, concentration of contrast material, and clip orientation in clipped patients was studied. METHODS A phantom containing a clip was scanned with v...

متن کامل

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2014