The impact of temporal regularization on estimates of the BOLD hemodynamic response function: A comparative analysis
نویسندگان
چکیده
In fMRI data analysis it has been shown that for a wide range of situations the hemodynamic response function (HRF) can be reasonably characterized as the impulse response function of a linear and time invariant system. An accurate and robust extraction of the HRF is essential to infer quantitative information about the relative timing of the neuronal events in different brain regions. When no assumptions are made about the HRF shape, it is most commonly estimated using time windowed averaging or a least squares estimated general linear model based on either Fourier or delta basis functions. Recently, regularization methods have been employed to increase the estimation efficiency of the HRF; typically these methods produce more accurate HRF estimates than the least squares approach [Goutte, C., Nielsen, F.A., Hansen, L.K., 2000. Modeling the Haemodynamic Response in fMRI Using Smooth FIR Filters. IEEE Trans. Med. Imag. 19(12), 1188-1201.]. Here, we use simulations to clarify the relative merit of temporal regularization based methods compared to the least squares methods with respect to the accuracy of estimating certain characteristics of the HRF such as time to peak (TTP), height (HR) and width (W) of the response. We implemented a Bayesian approach proposed by Marrelec et al. [Marrelec, G., Benali, H., Ciuciu, P., Pelegrini-Issac, M., Poline, J.-B., 2003. Robust Estimation of the Hemodynamic Response Function in Event-Related BOLD fMRI Using Basic Physiological Information. Hum. Brain Mapp. 19, 1-17., Marrelec, G., Benali, H., Ciuciu, P., Poline, J.B. Bayesian estimation of the hemodynamic of the hemodynamic response function in functional MRI. In: R. F, editor; 2001; Melville. p 229-247.] and its deterministic counterpart based on a combination of Tikhonov regularization [Tikhonov, A.N., Arsenin, V.Y., 1977. Solution of ill-posed problems. Washington DC: W.H. Winston.] and generalized cross-validation (GCV) [Wahba, G., 1990. Spline Models for Observational Data. Philadelphia: SIAM.] for selecting the regularization parameter. The performance of both methods is compared with least square estimates as a function of temporal resolution, color and strength of the noise, and the type of stimulus sequences used. In almost all situations, under the considered assumptions (e.g. linearity, time invariance and smooth HRF), the regularization-based techniques more accurately characterize the HRF compared to the least-squares method. Our results clarify the effects of temporal resolution, noise color, and experimental design on the accuracy of HRF estimation.
منابع مشابه
Locally Estimated Hemodynamic Response Function and Activation Detection Sensitivity in Heroin-Cue Reactivity Study
Introduction: A fixed hemodynamic response function (HRF) is commonly used for functional magnetic resonance imaging (fMRI) analysis. However, HRF may vary from region to region and subject to subject. We investigated the effect of locally estimated HRF (in functionally homogenous parcels) on activation detection sensitivity in a heroin cue reactivity study. Methods: We proposed...
متن کاملA Mixed L2 Norm Regularized HRF Estimation Method for Rapid Event-Related fMRI Experiments
Brain state decoding or "mind reading" via multivoxel pattern analysis (MVPA) has become a popular focus of functional magnetic resonance imaging (fMRI) studies. In brain decoding, stimulus presentation rate is increased as fast as possible to collect many training samples and obtain an effective and reliable classifier or computational model. However, for extremely rapid event-related experime...
متن کاملEvaluation of Hemodynamic Response Function in Vision and Motor Brain Regions for the Young and Elderly Adults
Introduction: Prior studies comparing Hemodynamic Response Function (HRF) in the young and elderly adults based on fMRI data have reported inconsistent findings for brain vision and motor regions in healthy aging. It is shown that the averaging method employed in all previous works has caused this inconsistency. The averaging is so sensitive to outliers and noise. However, fMRI data are o...
متن کاملTotal activation: fMRI deconvolution through spatio-temporal regularization
Confirmatory approaches to fMRI data analysis look for evidence for the presence of pre-defined regressors modeling contributions to the voxel time series, including the BOLD response following neuronal activation. As more complicated questions arise about brain function, such as spontaneous and resting-state activity, new methodologies are required. We propose total activation (TA) as a novel ...
متن کاملJoint maximum likelihood estimation of activation and Hemodynamic Response Function for fMRI
Blood Oxygen Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) maps the brain activity by measuring blood oxygenation level, which is related to brain activity via a temporal impulse response function known as the Hemodynamic Response Function (HRF). The HRF varies from subject to subject and within areas of the brain, therefore a knowledge of HRF is necessary for accurately c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2008