Advances in optically pumped He4 magnetometers : Resonance and nonresonance techniques
نویسنده
چکیده
2014 Samples of optically pumped 23S1 helium atoms are currently studied in our laboratory for use in advanced magnetometer applications. The results of recent investigations of the effect of pumping beam orientation with respect to the observed magnetic field are presented in this paper. The orientation dependence of the amplitude and frequency of the magnetic resonance signal observed by optical techniques has been measured. These results are used to predict the effect of orientation on scalar field change measurements. The experiments are theoretically interpreted by taking into account the contribution of the individual magnetic resonances and the perturbation of magnetic states by real and virtual transitions. The orientation dependence of the optical pumping process is used to construct a nonresonance magnetometer (no magnetic resonance) suitable for measuring vector interplanetary and laboratory fields in the range 2014 200 03B3 ~ H ~ 200 03B3. Several new optical pumping components which have contribued to the advancement of helium magnetometers are discussed. REVUE DE PHYSIQUE APPLIQUÉE TOME 5, FÉVRIER 1970, PAGE
منابع مشابه
Measurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers
Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...
متن کاملHigh Sample Rate Optically Pumped Helium Magnetometer
Optically pumped helium magnetometers are important instruments whichhave many applications in military, mass spectroscopy and space applications. In thispaper, the working principles of helium magnetometers have been explained. There isalso an introduction of a new method for finding the resonant frequency, which hasadvantages to the typical method such as more sample r...
متن کاملOptically pumped alkali magnetometers for biomedical applications
20 Optically pumped atomic magnetometers measure the Larmor frequency νL at which the bulk magnetization of a spin-polarized alkali metal vapour in a glass cell precesses around the field of interest B0. !e precession frequency is related to the modulus of the magnetic field by νL=(γ/2π)|B0|, where γ/2π≈3.5Hz/nT for 133Cs, so that the magnetic field measurement consists in a frequency measureme...
متن کامل4He optical pumping with intensity modulated laser light
4He (2 3Si) metastable atoms are optically pumped with intensity modulated light The use of a single mode diode-pumped LNA laser as the pumping source, allows the study of resonance signals predicted'by the optical pumping theory but not yet observed Resonances are detected on the transmitted pumping beam at the modulation frequency and its harmonics Application of this method to high sensitivi...
متن کاملMagnetocardiography measurements with 4He vector optically pumped magnetometers at room temperature.
In this paper, we present a proof of concept study which demonstrates for the first time the possibility of recording magnetocardiography (MCG) signals with 4He vector optically pumped magnetometers (OPM) operated in a gradiometer mode. Resulting from a compromise between sensitivity, size and operability in a clinical environment, the developed magnetometers are based on the parametric resonan...
متن کامل