Low-flow sevoflurane compared with low-flow isoflurane anesthesia in patients with stable renal insufficiency.
نویسندگان
چکیده
BACKGROUND Sevoflurane is degraded to compound A (CpA) by carbon dioxide absorbents containing strong base. CpA is nephrotoxic in rats. Patient exposure to CpA is increased with low fresh gas flow rates, use of Baralyme, and high sevoflurane concentrations. CpA formation during low-flow and closed circuit sevoflurane anesthesia had no significant renal effects in surgical patients with normal renal function. Preexisting renal insufficiency is a risk factor for postoperative renal dysfunction. Although preexisting renal insufficiency is not affected by high-flow sevoflurane, the effect of low-flow sevoflurane in patients with renal insufficiency is unknown. METHODS After obtaining institutional review board approval, 116 patients with a stable preoperative serum creatinine concentration 1.5 mg/dl or greater were assessable. Patients were randomized to receive either sevoflurane (n = 59, 0.8-2.5 vol%) or isoflurane (n = 57, 0.5-1.4 vol%) at a fresh gas flow rate of 1 l/min or less. Use of opioids was restricted to a minimum, and Baralyme was used to increase CpA exposure. Inspiratory and expiratory CpA concentrations were measured during anesthesia. Renal function (serum creatinine and blood urea nitrogen, urine protein and glucose, creatinine clearance) was measured preoperatively and 24 and 72 h after induction. RESULTS Demographic patient data did not differ between groups. Patients received 3.1 +/- 2.4 minimum alveolar concentration-hours sevoflurane or 3.8 +/- 2.6 minimum alveolar concentration-hours isoflurane (mean +/- SD). Durations of low flow were 201.3 +/- 98.0 and 213.6 +/- 83.4 min, respectively. Maximum inspiratory CpA with sevoflurane was 18.9 +/- 7.6 ppm (mean +/- SD), resulting in an average total CpA exposure of 44.0 +/- 30.6 ppm/h. There were no statistically significant changes from baseline to 24- and 72-h values for serum creatinine or blood urea nitrogen, creatinine clearance, urine protein, and glucose, nor were there significant differences between both anesthetics. CONCLUSION There were no statistically significant differences in measured parameters of renal function after low-flow sevoflurane anesthesia compared with isoflurane. These results suggest that low-flow sevoflurane anesthesia is as safe as low-flow isoflurane and does not alter kidney function in patients with preexisting renal disease.
منابع مشابه
Hemodynamic Parameters of Low-Flow Isoflurane and Low-Flow Sevoflurane Anesthesia During Controlled Ventilation With Laryngeal Mask Airway
BACKGROUND Nowadays laryngeal mask airway (LMA) is popular as one of the best choices for airway management. Low-flow anesthesia has some advantages like lower pollution, hemodynamic stability and cost effectiveness. Volatile anesthetics are widely used for anesthesia maintenance during operations. Sevoflurane has more hemodynamic stability compared to isoflurane, but there are few studies comp...
متن کاملA comparison of renal responses to sevoflurane and isoflurane in patients undergoing donor nephrectomy: a randomized controlled trial
Sevoflurane and isoflurane are volatile halogenated ether widely used in anesthesia. Both have comparable potency and easy titratability but sevoflurane has lower pungency and results in faster patient recovery. Isoflurane, however, is more affordable. The nephrotoxicity of sevoflurane is undisputed but studies on isoflurane nephrotoxicity are lacking. The objective of this paper is to determin...
متن کاملEffects of low-flow sevoflurane anesthesia on renal function in low birth weight infants
BACKGROUND Low-flow sevoflurane anesthesia has been shown to influence renal function in rats, but not in adult humans. Presently, no study has assessed the effects of sevoflurane on renal function in low birth weight infants. Our aim was to study the renal function in low birth weight infants undergoing surgery with low-flow sevoflurane anesthesia. METHODS Forty infants graded as American So...
متن کاملIs Spinal Anesthesia with Low Dose Lidocaine Better than Sevoflorane Anesthesia in Patients Undergoing Hip Fracture Surgery
Background: To evaluate general anesthesia with sevoflurane vs spinal anesthesia with low dose lidocaine 5% onhemodynamics changes in patients undergoing hip fracture surgery.Methods: In this randomized double blind trial 100 patients (50 patients in each group) older than 60 years underhip surgery were randomized in general anesthesia with sevoflurane and spinal anesthesia with lidocaine 5%.He...
متن کاملEffects of probenecid on renal function in surgical patients anesthetized with low-flow sevoflurane.
BACKGROUND Dehydrofluorination of sevoflurane by carbon dioxide absorbents in anesthesia machines produces compound A, which is nephrotoxic in rats. Several clinical studies indicate that prolonged low-flow sevoflurane anesthesia is associated with an increased urinary excretion of biochemical markers, such as protein. Probenecid, a competitive inhibitor of organic anion transport, diminishes c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 97 3 شماره
صفحات -
تاریخ انتشار 2002