Abdominal aorta aneurysm: Case report of high radiation dose during stent-graft implantation
نویسندگان
چکیده
This study is a case report regarding a possible problem of high radiation dose during stent-graft implantation. Before deciding on how to treat an aneurysm (stent grafting or traditional surgery), possible complications such as difficult anatomical conditions and diseases of the aorta and iliac arteries should be considered to avoid potentially high doses of radiation. In case of this patient, it was very difficult to introduce a guidewire through the contralateral limb into the body of the graft due to tortuosity and kinking of iliac arteries. Because of the long duration of the procedure (68 min), the patient was exposed to a very high radiation dose (4.37 Gy) and DAP (1760.3 Gy cm(2)).
منابع مشابه
Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent
Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...
متن کاملManagement of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report
Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75–years-o...
متن کاملAortic Dissection Occurring 18 Months after Successful Endovascular Repair in an Anatomically Difficult Case of Abdominal Aortic Aneurysm
We report an autopsy case of aneurysm dissection that occurred 18 months after the implantation of a Zenith stent graft. A 94-year-old woman, who had undergone an endovascular repair with postoperative reintervention, died of shock due to retroperitoneal hematoma. An autopsy indicated that the stent graft remained firmly fixed to the native aorta, whereas the dissection occurred near the proxim...
متن کاملDelayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature
OBJECTIVES To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. METHODS A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. RESULTS Seven years after the initial repair, imaging surveillance re...
متن کاملJuxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus
Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook's modular abdominal aortic aneurysm (AAA) graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 76 شماره
صفحات -
تاریخ انتشار 2011