Providing a fast conversion of total dose to biological effective dose (BED) for hybrid seed brachytherapy

نویسندگان

  • Jakub Pritz
  • Kenneth M. Forster
  • Amarjit S. Saini
  • Matthew C. Biagioli
  • Geoffrey G. Zhang
چکیده

Optimization of permanent seed implant brachytherapy plans for treatment of prostate cancer should be based on biological effective dose (BED) distributions, since dose does not accurately represent biological effects between different types of sources. Currently, biological optimization for these plans is not feasible due to the amount of time necessary to calculate the BED distribution. This study provides a fast calculation method, based on the total dose, to calculate the BED distribution. Distributions of various numbers of hybrid seeds were used to calculate total dose distributions, as well as BED distributions. Hybrid seeds are a mixture of different isotopes (in this study (125)I and (103)Pd). Three ratios of hybrid seeds were investigated: 25/75, 50/50, and 75/25. The total dose and BED value from each voxel were coupled together to produce graphs of total dose vs. BED. Equations were then derived from these graphs. The study investigated four types of tissue: bladder, rectum, prostate, and other normal tissue. Equations were derived from the total dose - BED correspondence. Accuracy of conversion from total dose to BED was within 2 Gy; however, accuracy of conversion was found to be better for high total dose regions as compared to lower dose regions. The method introduced in this paper allows one to perform fast conversion of total dose to BED for brachytherapy using hybrid seeds, which makes the BED-based plan optimization practical. The method defined here can be extended to other ratios, as well as other tissues that are affected by permanent seed implant brachytherapy (i.e., breast).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1

Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...

متن کامل

Evaluation of the interfractional biological effective dose (BED) variation in MammoSite high dose rate brachytherapy

The objective of this work is to evaluate the interfractional biological effective dose (BED) variation in MammoSite high dose rate (HDR) brachytherapy. Dose distributions of 19 patients who received 34 Gy in 10 fractions were evaluated. A method was employed to account for nonuniform dose distribution in the BED calculation. Furthermore, a range of alpha/beta values was utilized for specific c...

متن کامل

Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

متن کامل

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

متن کامل

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012