Safe human exposure limits for airborne linear siloxanes during spaceflight

نویسندگان

  • Valerie E. Meyers
  • Hector D. García
  • Tami S. McMullin
  • Joseph M. Tobin
  • John T. James
چکیده

BACKGROUND Low molecular weight siloxanes are used in industrial processes and consumer products, and their vapors have been detected in the atmospheres of the Space Shuttle and International Space Station. Therefore, the National Aeronautics and Space Administration (NASA) developed spacecraft maximum allowable concentrations (SMACs) for siloxane vapors to protect astronaut health. Since publication of these original SMACs, new studies and new risk assessment approaches have been published that warrant re-examination of the SMACs. OBJECTIVE To reevaluate SMACs published for octamethyltrisiloxane (L3) for exposures ranging from 1 hour to 180 days, to develop a 1000-day SMAC, and to expand the applicability of those values to the family of linear siloxanes. METHODS A literature review was conducted to identify studies conducted since the SMACs for L3 were set in 1994. The updated data were reviewed to determine the sensitive toxicity endpoints, and current risk assessment approaches and methods for dosimetric adjustments were evaluated. RESULTS Recent data were used to update the original 1-hour, 24-hour, 30-day, and 180-day SMACs for L3, and a 1000-day SMAC was developed to protect crewmembers during future exploration beyond Earth orbit. Group SMACs for the linear siloxane family, including hexamethyldisiloxane (L2), L3, decamethyltetrasiloxane (L4), and dodecamethylpentasiloxane (L5), were set for exposures of 1-hour to 1000 days. CONCLUSION New SMACs, based on acute pulmonary and neurotoxicity at high doses only achievable with L2 and potential liver effects following longer-term exposures to L2 and L3, were established to protect crewmembers from the adverse effects of exposure to linear siloxanes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exposure of school children to alpha particles

Background: A substantial part of the public’s natural radiation dose is due to the inhalation of radon gas. Most of the exposure occurs indoors where the airborne concentration of radon and its decay products is usually higher than outdoors. Materials and Methods: Radon activity concentration has been measured twice in 50 classrooms in 5 levels (10 each) during summer and winter using solid-st...

متن کامل

Animals and spaceflight: from survival to understanding.

Animals have been a critical component of the spaceflight program since its inception. The Russians orbited a dog one month after the Sputnik satellite was launched. The dog mission spurred U.S. interest in animal flights. The animal missions proved that individuals aboard a spacecraft not only could survive, but also could carry out tasks during launch, near-weightlessness, and re-entry; human...

متن کامل

Low-toxicity dusts: current exposure guidelines are not sufficiently protective.

Exposure to low-toxicity dusts, which have previously been viewed as 'nuisance dusts', can cause chronic obstructive pulmonary disease or other nonmalignant respiratory disease. In Britain, the 'de facto' airborne exposure limits for these dusts have remained unchanged for >30 years; currently, they are 10mg m(-3) for inhalable dust and 4mg m(-3) for respirable dust. During this time, exposures...

متن کامل

Control Banding in the Pharmaceutical Industry

The pharmaceutical industry embraced the concept of control banding many years ago. Control banding is a process of assigning a compound to a hazard category that corresponds to a range of airborne concentrations – and the engineering controls, administrative controls, and personal protective equipment – needed to ensure safe handling. While the terminology used was different, the high potency ...

متن کامل

How To Interpret Laboratory Results for Airborne Fungal (Mould) Samples

Introduction Laboratory results for airborne mould and bacteria concentrations can be difficult to interpret for two major reasons. First, there are no set maximum exposure limits (MELs) or threshold level values for airborne indoor mould and bacteria concentrations. Setting MELs would be difficult due to limitations in air sampling techniques (Kung’u, 2004), variability in sensitivity to micro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2013