Elevation of circulating HLA DR+ CD8+ T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty
نویسندگان
چکیده
BACKGROUND AND PURPOSE Following metal-on-metal hip arthroplasty (THA), immunological reactions including changes in lymphocyte populations, aseptic loosening, and lymphocytic pseudotumors occur. We hypothesized that changes in lymphocyte subpopulations would be associated with elevated metal ion concentrations. METHODS A randomized trial involving 85 patients matched for age and sex and randomized to receiving metal-on-metal (n = 41) or metal-on-polyethylene total hip arthroplasty (n = 44) was conducted. 36 patients were eligible for follow-up after mean 7 (6-8) years. Concentrations of chromium and cobalt were analyzed by high-resolution inductively coupled plasma mass spectrometry. Leukocyte subpopulations and immunoglobulins in patient blood were measured using standard laboratory methods. RESULTS Patients with a metal-on-metal hip had higher serum concentrations of chromium (1.05 vs. 0.36 μg/L; p < 0.001) and cobalt (0.86 vs. 0.24 μg/L; p < 0.001) than those with metal-on-polyethylene. The percentage of HLA DR(+) CD8(+) T-cells was higher in the metal-on-metal group (10.6 vs. 6.7%; p = 0.03) and correlated positively with chromium and cobalt concentrations in patient blood (Pearson's correlation coefficient: 0.39, p = 0.02; 0.36, p = 0.03, respectively). The percentage of B-cells was lower in the metal-on-metal group (p = 0.01). The two groups were similar with respect to immunoglobulin concentrations and Harris hip scores, and there were no radiographic signs of loosening. INTERPRETATION We conclude that immunological alterations appear to be associated with increased cobalt and chromium concentrations. It is tempting to speculate that HLA DR(+) CD8(+) T-cells are involved in the pathogenesis of allergic reactions, implant loosening, and lymphocytic pseudotumors.
منابع مشابه
Elevation of circulating HLA DR+ CD8+ T-cells and correla- tion with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty A randomized trial
Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2010.548028 Background and purpose Following metal-on-metal hip arthroplasty (THA), immunological reactions including changes in lymphocyte popula...
متن کاملMetal ion levels and lymphocyte counts: ASR hip resurfacing prosthesis vs. standard THA
BACKGROUND AND PURPOSE Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) and investigated whether cobalt and chromium ions affected the lymphocyte counts. METHOD In a randomi...
متن کاملCirculating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia.
We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating ...
متن کاملThe association between metal ions from hip resurfacing and reduced T-cell counts.
We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologi...
متن کاملIn vivo study on metal release from fixed orthodontic appliances in oral mucosa cells
In vivo study on metal release from fixed orthodontic appliances in oral mucosa cells Dr. F. Amini* - Dr. M. Rabbani** - Dr. A. Amjadei*** *- Assistant Professor of Orthodontics Dept. - Faculty of Dentistry – Islamic Azad University (Tehran). **- Assistant Professor, Nuclear Research Center Dept. Iranian Atomic Energy Organ. ***- Dentist. Background and Aim: Fixed orthodontic appliances usually...
متن کامل