Dual poly liner mobility optimizes wear and stability in THA: opposes.
نویسندگان
چکیده
Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) before neck-socket impingement occurs. Increasing ROM, however, introduces an additional problem of bony impingement of the trochanter against the pelvis. Consequently, there is little improvement in ROM for heads >36 to 40 mm. A 0.4% incidence of instability at the larger articulation has been reported in primary THA using the dual-mobility liner, which is equivalent to reports for conventional THA. The dual-mobility liner has introduced the unique complication of intraprosthetic dislocation, where the femoral head dissociates at the smaller articulation as a result of polyethylene wear. An incidence of intraprosthetic dislocation of 3.6% has been reported, which far exceeds dislocation of conventional arthroplasty. The dual-mobility liner is a monoblock acetabular component without the capacity for augmented bony fixation. Inability to achieve primary stability has been reported as high as 18% and therefore its usefulness in revision THA is questionable. Proponents of the dual-mobility liner cite improved wear characteristics over conventional THA; however, few studies support this proposition. Retrieval studies have reported that the dual-mobility liner does not avoid wear or osteolysis. Theoretically, it is inconceivable that wear would be diminished with an additional articulation with a huge surface area, where the differential hardness has been reversed to a soft-on-hard bearing.
منابع مشابه
Dual poly liner mobility optimizes wear and stability in THA: affirms.
A dual-mobility acetabular component consists of a large, fixed, porous-coated acetabular component and a bipolar femoral component. These components are often called tripolar components. This configuration provides a stable, well-fixed implant platform against bone and 2 articular interfaces, a large polyethylene surface directly apposed to a highly polished metal implant, and a standard-sized...
متن کاملEarly Intraprosthetic Dislocation of Dual- Mobility Total Hip Arthroplasty Implant Following Attempted Closed Reduction: A Case Report
Introduced in 1974 by Bousquet, the dual-mobility bearing for use in total hip arthroplasty (THA) confers increased jump distance and improved overall stability relative to conventional THA designs [1-3]. The dual-mobility bearing incorporates a relatively small (22-28mm) metal or ceramic femoral head press fit into a larger polyethylene liner which articulates with the acetabular component. Di...
متن کاملUnderstanding the Dual mobility concept for total hip arthroplasty. Investigations on a multiscale analysis-Highlighting the role of arthrofibrosis
In hip implants, UHMWPE (Ultra High Molecular Weight Polyethylene) liner wear is believed to be a key issue affecting the lifetime of the artificial joint. Dual mobility, a THA (Total Hip Arthroplasty) concept where the liner moves inside the metallic shell, has become popular due to its low dislocation rate. To understand the tribological behavior of this particular implant, especially the rol...
متن کاملConstrained liners, dual mobility or large diameter heads to avoid dislocation in THA
Dislocation remains a common cause of failure after total hip arthroplasty. The limitations of existing approaches to address instability have led to the development of powerfull options: constrained liners, dual mobility and large heads. These implant-related options have proven to be very efficient, but have raised concerns.With constrained liners, restricted range of motion (ROM) is responsi...
متن کاملDual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation
BACKGROUND AND PURPOSE Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA. PATIENTS AND METHODS 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a sp...