Comparison of Xe-133 washout and single-breath imaging for the detection of ventilation abnormalities.

نویسندگان

  • P O Alderson
  • H Lee
  • W R Summer
  • A Motazedi
  • H N Wagner
چکیده

The Xe-133 ventilation studies of 115 patients were analyzed to determine the relative abilities of the single-breath and washout phases to detect regional ventilation abnormalities. All Xe-133 images were obtained in the posterior projection before 6-view perfusion studies with Tc-99m human albumin microspheres. There were 275 regions with matching V-P abnormalities in the patients. The washout portion of the study detected 258 of these regions (94%) and the single breath detected 175 (64%) (p less than 0.01). The discrepancies were confined to regions with nonsegmental perfusion defects, where the single breath detected 139 matches and the washout 216. The discrimination ratio between normal areas and areas of obstructive lung disease improved from 2 to 1 after 1 min washout to 30 to 1 after 5 min. The late phases of Xe-133 washout are useful in detecting ventilation abnormalities, especially those associated with nonsegmental perfusion defects.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical comparison of Xe-127 and Xe-133 for ventilation studies.

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and appropriate collimation. A ...

متن کامل

Regional ventilation studies with Kr-81m and Xe-133: a comparative analysis.

Krypton-81m and Xe-133 ventilation scintigrams, and particulate per fusion scintigrams with Tc-99m, were obtained on the same day in 41 pa tients. Of 14 studies demonstrating pulmonary embolism, Kr-81m corn plernented the perfusion study better than Xe-133 in seven and was judged essential for that diagnosis in two. Xenon-133 was better in none. On the other hand, in 29 studies with obstructive...

متن کامل

Comparison of Quantitative Ventilation-Perfusion Lung Scan Results Using Different Xenon-133 Ventilation Images

Objective: This paper evaluates the influence of the specific Xe ventilation images used to calculate differential function in quantitative ventilation-perfusion lung scans. Methods: Whole-lung differentials were determined on 43 Xe ventilationfl mTc-macroaggregated albumin perfusion studies. Ventilation calculations were performed for the firstbreath, up to three equilibrium and the composite ...

متن کامل

Multiple breath washout of hyperpolarized 129Xe and 3He in human lungs with three‐dimensional balanced steady‐state free‐precession imaging

PURPOSE To compare quantitative fractional ventilation measurements from multiple breath washout imaging (MBW-I) using hyperpolarized 3 He with both spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) three-dimensional (3D) pulse sequences and to evaluate the feasibility of MBW-I with hyperpolarized 129 Xe. METHODS Seven healthy subjects were scanned using 3 He MBW-...

متن کامل

New 133Xe gas trapping index for quantifying severe emphysema before partial lung volume reduction.

UNLABELLED Lung volume reduction (LVR) is an effective therapy for end-stage emphysema. Preliminary and postprocedure imaging is usually limited to CT for anatomic delineation of the location and severity of the most acutely affected lung zones. The purpose of this study was to investigate the potential of using a new quantitative gas trapping index (GTI) derived from a (133)Xe ventilation scan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 1979