Development of a sampling and analysis method for 4-vinyl-1-cyclohexene in air.

نویسندگان

  • Pornpimol Kongtip
  • Bantoon Tangprakorn
  • Witaya Yoosook
  • Suttinun Chantanakul
چکیده

The purpose of this research was to develop an applicable sampling and analytical method to determine airborne 4-vinyl-1-cyclohexene concentrations which are usually found in the atmosphere of polybutadiene factories. A solid sorbent tube, containing two sections (100 mg in the front and 50 mg in the back) of activated coconut-shell charcoal was chosen for sampling 4-vinyl-1-cyclohexene vapor. The 4-vinyl-1-cyclohexene in the charcoal samples was desorbed with carbon disulfide and analyzed by gas chromatography equipped with a flame ionization detector. The suitable air flow rate, adsorption capacity, sample storage stability, desorption efficiency and reliability of the method for sampling and analysis of 4-vinyl-1-cyclohexene were evaluated. The method was applied to sampling and analysis of 4-vinyl-1-cyclohexene in the rubber industry. The results indicated a suitable air flow rate of 0.3 to 1.5 l/min. The adsorption capacity of 4-vinyl-1-cyclohexene on 100 mg of charcoal was 0.2134 mg. The 4-vinyl-1-cyclohexene adsorbed on the charcoal was stable for 7 d at room temperature or 21 d in a refrigerated condition. The average percent desorption efficiency of 4-vinyl-1-cyclohexene ranged from 90.45% to 97.04% with the loaded amount ranging from 0.412 to 8.250 microg using 1 ml carbon disulfide. The limit of detection of 4-vinyl-1-cyclohexene was 0.044 ng. The average percent recoveries (n=6) of 4-vinyl-1-cyclohexene adsorbed on charcoal ranging from 0.46 to 8.87 microg were 96.78-102.87% with relative standard deviations (RSDs) of 0.34-1.92%, respectively. The concentrations of 4-vinyl-1-cyclohexene ranged from 0.011 to 0.105 mg/m(3) in the working environment of a polybutadiene factory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Method Based on the Needle-trap Microextraction Filled with Hydroxyapatite and Polyaniline Nanocomposite for Determination of Volatile Organic Compounds in the Air

In this study, the efficiency of packed needle trap with hydroxyapatite/polyaniline (NTD-HAP/PA) nanocomposite was assessed in air sampling and analysis of a hazardous group of VOCs such as benzene, toluene, ethylbenzene and xylenes. The effects of main parameters, including desorption temperature and time, were evaluated on the performance and carryover of prepared NTDs. Moreover, the repeatab...

متن کامل

Uncatalyzed Synthesis of Arylmethylene[bis(5,5-dimethyl-3-hydroxy-2-cyclohexene-1-ones)] in Hot Water by Domino Knoevenagel/Michael Reactions

A simple and ecofriendly method was developed for the synthesis of arylmethylene[bis(5,5- dimethyl-3-hydroxy-2-cyclohexene-1-ones)] from the reaction of 5,5-dimethylcyclohexane- 1,3-dione and aromatic aldehydes in an aqueous media without any catalyst via Knoevenagel condensation followed by rapid Michael addition. No cyclization product was down to convert these enolic forms to xanthene deriva...

متن کامل

کاربرد روش تله سوزنی (Needle Trap) در تعیین مقدار ترکیبات ارگانوهالوژن در هوا

  Background and aim s : The correct assessment of volatile organic compounds is a main stage of their control's action plan. Needle trap device (NTD) as a novel technique with all advantages of microextraction methods, is an inexpensive and rapid technique for survey of air pollution agents. In this study the performance of this technique was investigated for sampling and analysis of organohal...

متن کامل

A Fast Method for Synthesis Magnesium Hydroxide Nanoparticles, Thermal Stable and Flame Retardant Poly vinyl alcohol Nanocomposite

Magnesium hydroxide nanostructures as an effective flame retardant were synthesized by a facile and rapid microwave reaction. The effect of different surfactants such as cationic, anionic and polymeric on the morphology of magnesium hydroxide nanostructures was investigated. Nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform in...

متن کامل

Fast and Sensitive Determination of Acetic Anhydride in the Air Using Hollow Fiber Method

This study aimed to introduce a new method based on Hollow Fiber in order to determination of acetic anhydride (AA) in the air. Hydroxylamine hydrochloride and sodium hydroxide (1:1), were used as extraction solvent. This method was studied in the laboratory under various conditions. In order to make different concentrations of AA in the air, a standard glass chamber was used. The optimization ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational health

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2008