Performance of multi-element CdZnTe detectors
نویسندگان
چکیده
Single-element CdZnTe detectors are limited in size, and therefore efficiency, by the poor hole transport, even with a coplanar grid. We are investigating the possibility of a 27-element (3 × 3 × 3) array using 15 mm × 15 mm × 15 mm elements for gamma-ray energies to 10 MeV for NASA planetary missions. We present experimental results for combinations of various size coplanar grid detectors using NIM electronics and energies to 6.1 MeV. Summation of the signals after linear gating and requiring coincidence produces only a small increase in the energy resolution. Our results indicate that good efficiency and a spectrum not complicated by a large Compton continuum can be achieved by simply summing the spectra from 15 × 15 × 15 mm detectors for gamma-ray energies below about 2 MeV. Above 2 MeV, 2-fold coincidence might be required, depending on the spectrum, to suppress the Compton continuum and escape peaks. We use a Monte Carlo calculation to predict the performance of the 27-element array for a lunar highlands spectrum. Such ambienttemperature, high-efficiency, good-resolution arrays will facilitate new NASA missions to determine elemental composition of planetary bodies and terrestrial applications requiring high-efficiency, good-resolution portable instruments.
منابع مشابه
Performance Evaluation of New Generation CdZnTe Detectors for Safeguards Applications
Cadmium zinc telluride detectors (CdZnTe) have found a wide application in non-destructive assay measurements in the IAEA’s verification practice. It is because of their form factor, usability, sensitivity and good spectral characteristics that they are extensively used for fresh and spent fuel attribute test measurements. Until now, the series of CdZnTe detectors utilized in the IAEA have cove...
متن کاملImpact of drift time variation on the Compton image from large-volume CdZnTe crystals
In pixelated CdZnTe detectors, multiple interaction gamma-ray events are critical because they permit Compton imaging. However, in large-volume CdZnTe crystals, the depth of multiple interaction events is often poorly reconstructed due to significant nonuniformity of electron drift velocity while the depth of single interaction events can be accurately reconstructed using signal ratios. The non...
متن کاملDirect Conversion CdZnTe and CdTe Detectors for Digital Mammography
Hybrid CdZnTe and CdTe pixel detector arrays with 50 50 micron pixel sizes that convert x-rays directly into charge signals are under development at NOVA for applications to digital mammography. CdZnTe and CdTe have superior x-ray quantum efficiency compared to either emulsion-based film, phosphor-based detectors or other low-Z, solid-state detectors such as silicon. In this paper, latest resul...
متن کاملProgress in the Development of CdZnTe Unipolar Detectors for Different Anode Geometries and Data Corrections
CdZnTe detectors have been under development for the past two decades, providing good stopping power for gamma rays, lightweight camera heads and improved energy resolution. However, the performance of this type of detector is limited primarily by incomplete charge collection problems resulting from charge carriers trapping. This paper is a review of the progress in the development of CdZnTe un...
متن کاملTransport Properties and Performance of Cdznte Strip Detectors
| We report on recent tests and computer simulations of a sub-millimeter pitch CdZnTe strip detector under study as a prototype imaging spectrometer. This paper presents new measurements and new analyses of previous measurements of the CdZnTe transport properties for this prototype and resolves previously reported quantitative discrepancies. Measurements of charge signals produced by-rays are u...
متن کامل