Correction: Application and Evaluation of Interactive 3D PDF for Presenting and Sharing Planning Results for Liver Surgery in Clinical Routine

ثبت نشده
چکیده

The legends for S1 File and S2 File are incorrectly switched. Please view S1 File and S2 File with their correct legends below.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application and Evaluation of Interactive 3D PDF for Presenting and Sharing Planning Results for Liver Surgery in Clinical Routine

BACKGROUND & OBJECTIVES The Portable Document Format (PDF) is the de-facto standard for the exchange of electronic documents. It is platform-independent, suitable for the exchange of medical data, and allows for the embedding of three-dimensional (3D) surface mesh models. In this article, we present the first clinical routine application of interactive 3D surface mesh models which have been int...

متن کامل

Three-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog

Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...

متن کامل

HepaVision2 – A software assistant for preoperative planning in living-related liver transplantation and oncologic liver surgery

HepaVision2, a user friendly software application for preoperative planning based on CT images in liver surgery is presented. It is intended for both, evaluation of potential donors in living-related liver transplantation and planning of oncologic resections. The planning takes into account the patient’s individual anatomy allowing for fully automatic calculation of individual resection proposa...

متن کامل

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

متن کامل

I-44: 3D Ultrasonography of Ovarian Tumors

A prospective study was conducted at the OB/GYN department of Kasr El Eini hospital, Cairo University from Jan 2000 - Oct 2002. The study included 51 patients in the age group between 40-70 years (including pre and post menopausal women). All patients were subjected to following after taking a consent from each patient: Complete clinical evaluation; including history taking and clinical examina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015