An Adaptive Neuro-Fuzzy Inference System Based Modeling for Corrosion-Damaged Reinforced HSC Beams Strengthened with External Glass Fibre Reinforced Polymer Laminates
نویسندگان
چکیده
Problem statement: This study presents the results of ANFIS based model proposed for predicting the performance characteristics of reinforced HSC beams subjected to different levels of corrosion damage and strengthened with externally bonded glass fibre reinforced polymer laminates. Approach: A total of 21 beams specimens of size 150, 250×3000 mm were cast and tested. Results: Out of the 21 specimens, 7 specimens were tested without any corrosion damage (R-Series), 7 after inducing 10% corrosion damage (ASeries) and another 7 after inducing 25% corrosion damage (BSeries). Out of the seven specimens in each series, one was tested without any laminate, three specimens were tested after applying 3 mm thick CSM, UDC and WR laminates and another three specimens after applying 5mm thick CSM, UDC and WR laminates. Conclusion/Recommendations: The test results show that the beams strengthened with externally bonded GFRP laminates exhibit increased strength, stiffness, ductility and composite action until failure. An Adaptive Neuro-Fuzzy Inference System (ANFIS) model is developed for predicting the study parameters for input values lying within the range of this experimental study.
منابع مشابه
Strengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates
Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...
متن کاملAdaptive Neuro-Fuzzy Inference System Based Modeling for Fibre Reinforced Polymer Jacketed HSC Columns
–The paper presents the results of a study on the performance of Glass Fibre Reinforced Polymer (GFRP) wrapped high strength concrete columns under uni-axial compression. The columns had slenderness ratios of 8, 16, 24 and 32. Three types of wrap materials (Chopped Strand Mat GFRP, Uni-Directional Cloth GFRP and Woven Roving GFRP) were used with 3 mm and 5 mm thicknesses. The columns were teste...
متن کاملFRP Repair of Corrosion-Damaged Reinforced Concrete Beams
Corrosion of steel reinforcement is one of the main durability problems facing reinforced concrete infrastructures worldwide. This paper will summarize the results of a multi-phase experimental program undertaken at the University of Waterloo to investigate the viability of using externally bonded fiber reinforced polymer (FRP) laminates to rehabilitate corrosion-damaged reinforced concrete bea...
متن کاملAdaptive Neural Fuzzy Inference System Models for Predicting the Shear Strength of Reinforced Concrete Deep Beams
A reinforced concrete member in which the total span or shear span is especially small in relation to its depth is called a deep beam. In this study, a new approach based on the Adaptive Neural Fuzzy Inference System (ANFIS) is used to predict the shear strength of reinforced concrete (RC) deep beams. A constitutive relationship was obtained correlating the ultimate load with seven mechanical a...
متن کاملPerformance of Corrosion-Damaged HSC Beams Strengthened with GFRP Laminates
This paper presents the results of an experimental program conducted for evaluating the performance of corrosion damaged HSC beams strengthened with GFRP laminates. Five Beam specimens of size 150x250x3000 mm were caste and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as reference. Two beams were corroded to serve as corroded control. A ...