The potential role of human osteoblasts for periprosthetic osteolysis following exposure to wear particles.

نویسندگان

  • Katrin Lochner
  • Andreas Fritsche
  • Anika Jonitz
  • Doris Hansmann
  • Petra Mueller
  • Brigitte Mueller-Hilke
  • Rainer Bader
چکیده

Aseptic loosening in total hip replacement is mainly caused by wear particles inducing inflammation and osteolysis. Wear can be a consequence of micromotions at the interface between implant and bone cement. Due to complex cellular interactions, different mediators (e.g. cytokines, proteinases) are released, which can promote osteolytic processes in the periprosthetic tissue followed by loosening of the implant. Furthermore, a reduced matrix synthesis and an induced apoptosis rate can be observed. The purpose of this study was to evaluate to what extent human primary osteoblasts exposed to wear particles are involved in the osteolysis. The viability, the secretion of collagen and collagenases and the variety of released cytokines after particle exposure was examined. Therefore, human osteoblasts were incubated with particles experimentally generated in the interface between hip stems with rough and smooth surface finishings as well as different material compositions (Ti-6Al-7Nb, Co-28Cr-6Mo and 316L) and bone cement mantle made of Palacos R containing zirconium oxide particles. Commercially pure titanium particles, titanium oxide, polymethylmethacrylate and particulate zirconium oxide were used as references. The results revealed distinct effects on the cytokine release of human osteoblasts towards particulate debris. Thereby, human osteoblasts released increased levels of interleukine (IL)-6 and IL-8 after treatment with metallic wear particles. The expression of VEGF was slightly induced by all particle entities at lower concentrations. Apoptotic rates were enhanced for osteoblasts exposed to all the tested particles. Furthermore, the de novo synthesis of type 1 collagen was reduced and the expression of the matrix metalloproteinase (MMP)-1 was considerably increased. However, wear particles of Co-28Cr-6Mo stems seemed to be more aggressive, whereas particles derived from stainless steel stems caused less adverse cellular reaction. Among the reference particles, which caused less altered reactions in the metabolism of osteoblasts in general, ZrO2 can be assumed as the material with the smallest cell biological effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contribution of human osteoblasts and macrophages to bone matrix degradation and proinflammatory cytokine release after exposure to abrasive endoprosthetic wear particles

One of the major reasons for failure after total joint arthroplasty is aseptic loosening of the implant. At articulating surfaces, defined as the interface between implant and surrounding bone cement, wear particles can be generated and released into the periprosthetic tissue, resulting in inflammation and osteolysis. The aim of the present study was to evaluate the extent to which osteoblasts ...

متن کامل

Particle disease really does exist

© 2017 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) DOI 10.1080/17453674.2017.1402463 Sir,—In a recent correspondence, Dr. Mjöberg questions the role of wear particles in the pathogen...

متن کامل

Current research in the pathogenesis of aseptic implant loosening associated with particulate wear debris.

Periprosthetic osteolysis is the most common long-term complication of a total joint arthroplasty, often resulting in aseptic loosening of the implant, which occurs in up to 34% of younger implant recipients and usually requires surgical revision. Particulate wear debris, continuously generated by articulating motion at the bearing surfaces, has been implicated as one of the primary causes of p...

متن کامل

Wear particles and ions from cemented and uncemented titanium-based hip prostheses—A histological and chemical analysis of retrieval material

Wear debris-induced inflammation is considered to be the main cause for periprosthetic osteolysis in total hip replacements (THR). The objective of this retrieval study was to examine the tissue reactions and exposure to metal ions and wear particles in periprosthetic tissues and blood samples from patients with titanium (Ti)-based hip prostheses that were revised due to wear, osteolysis, and/o...

متن کامل

The Role of TLR and Chemokine in Wear Particle-Induced Aseptic Loosening

Wear particle-induced periprosthetic osteolysis remains the principal cause of aseptic loosening of orthopaedic implants. Monocytes/macrophages phagocytose wear particles and release cytokines that induce inflammatory response. This response promotes osteoclast differentiation and osteolysis. The precise mechanisms by which wear particles are recognized and induce the accumulation of inflammato...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of molecular medicine

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2011