High-throughput mutation detection method to scan BRCA1 and BRCA2 based on heteroduplex analysis by capillary array electrophoresis.

نویسندگان

  • Eva Esteban-Cardeñosa
  • Mercedes Duran
  • Mar Infante
  • Eladio Velasco
  • Cristina Miner
چکیده

BACKGROUND Scanning for mutations in BRCA1 and BRCA2 in a large number of samples is hampered by the large sizes of these genes and the scattering of mutations throughout their coding sequences. Automated capillary electrophoresis has been shown to be a powerful system to detect mutations by either single-strand conformation polymorphism or heteroduplex analysis (HA). METHODS We investigated the adaptation of gel-based HA of BRCA1 and BRCA2 to a fluorescent multicapillary platform to increase the throughput of this technique. We combined multiplex PCR, three different fluorescent labels, and HA in a 16-capillary DNA sequencer and tested 57 DNA sequence variants (11 insertions/deletions and 46 single-nucleotide changes) of BRCA1 and BRCA2. RESULTS We detected all 57 DNA changes in a blinded assay, and 2 additional single-nucleotide substitutions (1186 A>G of BRCA1 and 3624 A>G of BRCA2), previously unresolved by conformation-sensitive gel electrophoresis. Furthermore, different DNA changes in the same PCR fragment could be distinguished by their peak patterns. CONCLUSIONS Capillary-based HA is a fast, efficient, and sensitive method that considerably reduces the amount of "hands-on" time for each sample. By this approach, the entire coding regions of BRCA1 and BRCA2 from two breast cancer patients can be scanned in a single run of 90 min.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary and microchip electrophoresis for rapid detection of known mutations by combining allele-specific DNA amplification with heteroduplex analysis.

BACKGROUND Detection of mutations by gel electrophoresis and allele-specific amplification by PCR (AS-PCR) is not easily scaled to accommodate a large number of samples. Alternative electrophoretic formats, such as capillary electrophoresis (CE) and microchip electrophoresis, may provide powerful platforms for simple, fast, automated, and high-throughput mutation detection after allele-specific...

متن کامل

EMMA, a cost- and time-effective diagnostic method for simultaneous detection of point mutations and large-scale genomic rearrangements: application to BRCA1 and BRCA2 in 1,525 patients.

The detection of unknown mutations remains a serious challenge and, despite the expected benefits for the patient's health, a large number of genes are not screened on a routine basis. We present the diagnostic application of EMMA (Enhanced Mismatch Mutation Analysis(®) , Fluigent, Paris, France), a novel method based on heteroduplex analysis by capillary electrophoresis using innovative matric...

متن کامل

High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis.

We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to...

متن کامل

Mutation Detection by Single Strand Conformation Polymorphism and Heteroduplex Analysis

Single strand conformation polymorphism (SSCP) and heteroduplex analysis (HDA) are two of the most popular electrophoresis-based mutation detection methods. Coupled to DNA amplification of the sequence to be analyzed, these techniques have become the methods of choice for a number of molecular diagnostic laboratories. This can be explained mainly by the numerous advantages, namely their technic...

متن کامل

An improved high throughput heteroduplex mutation detection system for screening BRCA2 mutations-fluorescent mutation detection (F-MD).

We describe an improved, fast, automated method for screening large genes such as BRCA2 for germline genomic mutations. The method is based on heteroduplex analysis, and has been adapted for a high throughput application by combining the fluorescent technology of automated sequencers and robotic sample handling. This novel approach allows the entire BRCA2 gene to be screened with appropriate ov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2004