Development and validation of a stability-indicating HPLC assay method for simultaneous determination of spironolactone and furosemide in tablet formulation.

نویسندگان

  • Vijay R Ram
  • Pragnesh N Dave
  • Hitendra S Joshi
چکیده

The objective of the current study was to develop and validate a simple, precise and accurate isocratic stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) assay method for the determination of spironolactone and furosemide in solid pharmaceutical dosage forms. Isocratic RP-HPLC separation was achieved on an SGE 150 × 4.6 mm SS Wakosil II 5C8RS 5-μm column using a mobile phase of acetonitrile-ammonium acetate buffer (50:50, v/v) at a flow rate of 1.0 mL/min. The detection was carried out at 254 nm using a photodiode array detector. The drug was subject to oxidation, hydrolysis, photolysis and heat to apply stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and solution stability. The method was found to be linear in the drug concentration range of 40-160 µg/mL with correlation coefficients of 0.9977 and 0.9953 for spironolactone and furosemide, respectively. The precision (relative standard deviation; RSD) among a six-sample preparation was 0.87% and 1.1% for spironolactone and furosemide, respectively. Repeatability and intermediate precision (RSD) among a six-sample preparation were 0.46% and 0.20% for spironolactone and furosemide, respectively. The accuracy (recovery) was between 98.05 and 100.17% and 99.07 and 100.58% for spironolactone and furosemide, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of spironolactone and furosemide; therefore, the assay can be considered to be stability-indicating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2012