On the optimum distance for signal-energy mapping in extensive air shower arrays

نویسنده

  • G. Ros
چکیده

In high energy cosmic rays surface arrays, the primary energy is currently determined from the value of the lateral distribution function (LDF) at a fixed optimum distance ropt from the shower core. The value of ropt is mainly related to the geometry of the array and is, therefore, considered as fixed independently of the shower energy or direction. Here, we demonstrate that the dependence of ropt on energy and zenith angle is not negligible. As a consequence, this method may not reconstruct properly the shape of the spectrum and might change the position of spectral features like the ankle. This result applies for pure surface array experiments but not to hybrid experiments, like the Pierre Auger Observatory, where hybrid events are used to calibrate the reconstructed energy of surface events. Additionally, events with saturated stations must be either properly corrected or eliminated altogether from the analysis when applying the ropt method. We show that calculating a specific ropt on a shower-to-shower bases, instead of using a fixed value, may avoid the problem of events with saturated stations and improve, at the same time, the reconstruction of spectral features. 0 G. Ros: Tel/fax: +34-918854954/42. E-mail address: [email protected]. In collaboration with Universidad Complutense de Madrid and Universidad Nacional Autónoma de México. Preprint submitted to Elsevier 2 August 2009

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on the lateral distribution of Cherenkov light in extensive air showers

The dependence of the lateral distribution of Cherenkov light in simulated extensive air showers to the energy and the mass of the primary cosmic rays has been studied. It has been shown that a previous claim about mass independent proportionality of shower energy to the total Cherenkov photon number is not valid in energies below EEAS ~ 1014 eV. We have found that the core distance of the so c...

متن کامل

Angular deviation of secondary charge particles in 1014-1016 eV extensive air showers: Constrains on application of hodoscopes

  Deviation angles of secondary electrons and muons in simulated extensive air showers were studied. The angles have wide distribution, whose width depends on energy cuts imposed on shower particles. In this work, variation of deviation angles with the energy of secondary particles, shower energy, primary direction, and core distance was investigated. The results put limitations on application ...

متن کامل

ar X iv : a st ro - p h / 06 08 11 8 v 1 4 A ug 2 00 6 The Optimum Distance at which to Determine the Size of a Giant Air Shower

To determine the size of an extensive air shower it is not necessary to have knowledge of the function that describes the fall-off of signal size from the shower core (the lateral distribution function). In this paper an analysis with a simple Monte Carlo model is used to show that an optimum ground parameter can be identified for each individual shower. At this optimal core distance, r opt , t...

متن کامل

Simulation Calibration of an Extensive Air Shower array, by a logged data set of its small prototype

Alborz observatory is an EAS array in the heights of Alborez mountain chain near Tehran. For the development of the array, more number of detectors is inevitable. The managing the financial resources and achieving the highest efficiency of the array is important for the project. Therefore, Water Cherenkov Detectors has been used for 9 months in the same way as the previous experiment with Scint...

متن کامل

Progress in Air Shower Radio Measurements: Detection of Distant Events

Data taken during half a year of operation of 10 LOPES antennas (LOPES-10), triggered by EAS observed with KASCADE-Grande have been analysed. We report about the analysis of correlations of radio signals measured by LOPES-10 with extensive air shower events reconstructed by KASCADE-Grande, including shower cores at large distances. The efficiency of detecting radio signals induced by air shower...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009