Method dependence, observer variability and kidney volumes in radiation dosimetry of 177Lu-DOTATATE therapy in patients with neuroendocrine tumours

نویسندگان

  • Mattias Sandström
  • Ezgi Ilan
  • Anna Karlberg
  • Silvia Johansson
  • Nanette Freedman
  • Ulrike Garske-Román
چکیده

BACKGROUND Radionuclide therapy can be individualized by performing dosimetry. To determine absorbed organ doses in (177)Lu-DOTATATE therapy, three methods based on activity concentrations are currently in use: the small volume of interest (sVOI) method, and two methods based on large VOIs either on anatomical CT (aVOI) or on thresholds on functional images (tVOI). The main aim of the present work was to validate the sVOI in comparison to the other two methods regarding agreement and time efficiency. Secondary aims were to investigate inter-observer variability for the sVOI and the change of functional organ volumes following therapy. METHODS Thirty patients diagnosed with neuroendocrine tumours undergoing therapy with (177)Lu-DOTATATE were included. Each patient underwent three SPECT/CT scans at 1, 4 and 7 days after the treatment. Three independent observers calculated absorbed doses to the right and left kidney and the spleen using sVOI and one observer used aVOI. For tVOI, the absorbed doses were calculated based on automatically drawn isocontours around the organs at different thresholds (42, 50, 60 and 70 %). The inter-observer difference between the calculated absorbed doses for sVOI was calculated, and the differences between the three methods were computed. Ratios of organ volumes acquired at days 1, 4 and 7 versus the volume at day 1 were calculated for the tVOI method. RESULTS The differences in results of the absorbed dose calculations using all the sVOI and tVOI were small (<5 %). Absorbed dose calculations using aVOI differed slightly more from these results but were still below 10 %. The differences between the three dose calculation methods varied between <5 and 10 %. The organ volumes derived from the tVOI were independent of time for the spleen while they decreased with time for the kidneys. The fastest analysis was performed with the sVOI method. CONCLUSIONS All three dose calculation methods rendered comparable results with small inter-observer differences for sVOI. Unlike the spleen, the functional volume of the kidneys decreased over time during therapy, which suggests that the absorbed dose calculation for the kidneys on activity concentrations should be performed for each time point. The sVOI is the preferred method for calculating absorbed doses in solid organs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

SPECT image segmentation for estimation of tumour volume and activity concentration in 177Lu-DOTATATE radionuclide therapy

BACKGROUND Dosimetry in radionuclide therapy has the potential to allow for a treatment tailored to the individual patient. One therapeutic radiopharmaceutical where patient-specific dosimetry is feasible is 177Lu-DOTATATE, used for the treatment of neuroendocrine tumours. The emission of gamma photons by 177Lu allows for imaging with SPECT (single photon emission computed tomography). One impo...

متن کامل

Lutetium-177 DOTATATE Production with an Automated Radiopharmaceutical Synthesis System

Objective(s): Peptide Receptor Radionuclide Therapy (PRRT) with yttrium-90 (90Y) and lutetium-177 (177Lu)-labelled SST analogues are now therapy option for patients who have failed to respond to conventional medical therapy. In-house production with automated PRRT synthesis systems have clear advantages over manual methods resulting in increasing use in hospital-based radiopharmacies. We report...

متن کامل

The comparison of serial SPECT-CT imaging to estimate absorbed dose to the organ at risk from peptide receptor radionuclide therapy dosimetry

Introduction: In Peptide Receptor Radionuclide Therapy (PRRT), the administration of radionuclide such as Lu-177 label with a pharmaceutical agent useful to destroy the lesion. The amount of Lu-177 radioactivity administered to the patients is still not standardize and generally not more than 7.4 GBq per session due to the patient’s safety issues. The first cycle of Lu-177 is a...

متن کامل

Nephrotoxicity after PRRT - still a serious clinical problem? Renal toxicity after peptide receptor radionuclide therapy with 90Y-DOTATATE and 90Y/177Lu-DOTATATE.

INTRODUCTION The kidneys play an essential role in PRRT. The infusion of amino acids could reduce uptake in the kidney of radiolabelled peptides. The purpose of this study was to determine the extent of kidney damage post PRRT. MATERIAL AND METHODS 53 patients, with disseminated neuroendocrine tumours (NET), received 3-5 cycles of up to a maximum 7.4 GBq/m2 calculated dose of 90Y-DOTATATE (n ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015