Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction.

نویسندگان

  • B Guenoun
  • F Zadegan
  • F Aim
  • D Hannouche
  • R Nizard
چکیده

INTRODUCTION Several clinical and radiological techniques have been described to assess lower limb length and angle measurements. None of them has yet met the ideal criteria for a reliable, reproducible, safe, and inexpensive system. In this context, a new biplanar X-ray system (EOS™, EOS imaging, Paris, France) makes it possible to obtain a 3D reconstruction of the lower extremities from two 2D orthogonal radiographic images, with associated calculation of 3D measurements. The reliability of this technique has never been documented on adults. HYPOTHESIS Lower limb measurements produced by the 3D EOS™ reconstruction system are reproducible regarding inter- and intraobserver assessment and more reliable with this 3D technique than when they are obtained from 2D measurements. MATERIALS AND METHODS This study included 25 patients awaiting total hip arthroplasty (50 lower limbs). Two independent observers made all measurements twice, both on the 2D frontal radiograph and using 3D reconstructions (femoral measurements of length, offset, neck shaft angle, neck length, and head diameter, as well as the tibia length, limb length, HKA and HKS). Reproducibility was estimated by intraclass correlation coefficients. RESULTS Both the inter- and intraobserver reproducibility of the EOS™ measurements was excellent; more specifically inter- and intraobserver reproducibility was 0.997 and 0.997 for femoral length, 0.996 and 0.995 for tibial length, 0.999 and 0.999 for limb length, 0.894 and 0.891 for HKS, 0.993 and 0.994 for HKA, 0.870 and 0.845 for femoral offset, and 0.765 and 0.851 for neck shaft angle. For most of the variables, the interobserver correlations were statistically better with the EOS™ 3D reconstruction. DISCUSSION Our results show that the EOS™ systems allow reproducible lower limb measurements. Furthermore, 3D EOS™ reconstructions offer better reproducible measures for most of the parameters than radiographic 2D projection. Its use before deciding on surgery and during planning for lower limb arthroplasty appears essential to us. LEVEL OF EVIDENCE Level III: diagnostic prospective study on consecutive patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Application of Wavelet Neural Networks for Improving of Ionospheric Tomography Reconstruction over Iran

In this paper, a new method of ionospheric tomography is developed and evaluated based on the neural networks (NN). This new method is named ITNN. In this method, wavelet neural network (WNN) with particle swarm optimization (PSO) training algorithm is used to solve some of the ionospheric tomography problems. The results of ITNN method are compared with the residual minimization training neura...

متن کامل

Early Reconstructions of Complex Lower Extremity Battlefield Soft Tissue Wounds

BACKGROUND Severe lower extremity trauma as a devastating combat related injury is on the rise and this presents reconstructive surgeons with significant challenges to reach optimal cosmetic and functional outcomes. This study assessed early reconstructions of complex lower extremity battlefield soft tissue wounds. METHODS  This was a prospective case series study of battled field injur...

متن کامل

Test-retest reliability of Motricity Index strength assessments for lower extremity in post stroke hemiparesis

  Background: The Motricity Index was used to measure strength in upper and lower extremities after stroke. The weighted score based on the ordinal 6 point scale of Medical Research Council was used to measure maximal isometric muscle strength. There is dearth of articles dealing with the reliability of this method. Therefore, the aim of this study was to determine the test retest reliability o...

متن کامل

بررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا

Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 98 5  شماره 

صفحات  -

تاریخ انتشار 2012