Measurements of tissue blood flow by the hydrogen clearance technique (HCT): a comparative study including laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO).

نویسندگان

  • H G Machens
  • N Pallua
  • P Mailaender
  • J Pasel
  • K H Frank
  • R Reimer
  • A Berger
چکیده

The purpose of this study was to compare the hydrogen clearance technique (HCT) with two different, well-established techniques, i.e., the laser Doppler flowmetry (LDF) and the Erlangen micro-lightguide spectrophotometer (EMPHO), for tissue blood flow measurements in an experimental setting. For the animal experiments, we chose a rat model for arterial and venous flap thrombosis, using the epigastric groin flap. Forty male dark Aguty rats were included in the study. The animals were divided into eight groups, each with a different vascular thrombotic model. HCT was used to collect 1,467 measurements, and 2,934 graphs were recorded; 27 measurements (54 graphs) had to be discarded due to faulty electrode placements and electronic noise. In 19 of the 27 discarded measurements the cause of failure was moving of the awaking animal with disruption of the decay signal. The LDF and EMPHO measurements were performed continuously during each measuring phase. Simple and multiple linear regression and paired t-tests were used to compare the three techniques. The reproducibility of registered blood flow values in phases 1, 3, 6 and 7 varied between 7.8% and 13.6% which is in about the same range as LDF and EMPHO. We could not find a significant difference between the three techniques in this regard. The correlation coefficient for HCT and LDF was r = 0.89. For HCT and EMPHO we found r = 0.67. Sensitivity and specificity values for HCT were both 1.0 in detecting arterial and venous flap thrombosis; for LDF we found values of 0.89 and 0.92, respectively. Sensitivity and specificity values for EMPHO were 0.92 and 0.95, respectively. After careful evaluation of three different techniques (HCT, LDF, and EMPHO) for measurements of local tissue blood flow we came to the conclusion that HCT must be favoured as a reliable tool for quantitative measurement of local tissue blood flow and early diagnosis of arterial and venous flap thrombosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry

Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome  by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

Laser-Doppler flowmetry at large interoptode spacing in human tibia diaphysis: Monte Carlo simulations and preliminary experimental results.

Laser-Doppler flowmetry (LDF) is an outstanding tool to monitor blood flow in a continuous and non-invasive way. In this work, we study LDF at large interoptode spacing applied to a human bone model (i.e. tibia diaphysis). To that aim, we first performed an extensive set of Monte Carlo (MC) simulations for 10 and 25 mm interoptode spacing. Second, we have assembled a dedicated LDF instrumentati...

متن کامل

Time-domain algorithm for single-photon laser-Doppler flowmetry at large interoptode spacing in human bone.

A new laser-Doppler flowmeter at large interoptode spacing, based on single-photon counting (single-photon laser-Doppler flowmetry [SP-LDF]) and allowing assessment of blood flow deep in bone tissue, is proposed and implemented. To exploit the advantages of the new SP-LDF hardware, a dedicated simple and efficient time-domain algorithm has been developed. The new algorithm is based on the zero-...

متن کامل

Quantitative Laser Doppler Flowmetry

vii-Abstract Laser Doppler flowmetry (LDF) is virtually the only non-invasive technique, except for other laser speckle based techniques, that enables estimation of the microcirculatory blood flow. The technique was introduced into the field of biomedical engineering in the 1970s, and a rapid evolvement followed during the 1980s with fiber based systems and improved signal analysis. The first i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Microsurgery

دوره 16 12  شماره 

صفحات  -

تاریخ انتشار 1995