Using Body Mass Index to Predict Needle Length in Fluoroscopy-Guided Lumbar Punctures.

نویسندگان

  • A P Nayate
  • I M Nasrallah
  • J E Schmitt
  • S Mohan
چکیده

BACKGROUND AND PURPOSE Predicting the appropriate needle length to use in oblique interlaminar-approach fluoroscopy-guided lumbar punctures in patients with a large body mass index is difficult. Using the wrong needle length can lead to an increased radiation dose and patient discomfort. We hypothesized that body mass index could help determine the appropriate needle length to use in patients. MATERIALS AND METHODS We randomly selected patients who underwent oblique interlaminar-approach fluoroscopy-guided lumbar punctures and had cross-sectional imaging of the lumbar spine within 1 year of imaging (n = 50). The distance from the skin to the midlumbar spinal canal (skin-canal distance) at the level of the lumbar puncture was measured by using an oblique angle of 8.6°, which is an average of angles most often used to perform the procedure. A formula was devised using the skin-canal distance and body mass index to predict the appropriate needle length, subsequently confirmed in 45 patients. RESULTS The body mass index and skin-canal distance were significantly higher (P < .001) in patients who underwent fluoroscopy-guided lumbar puncture with 5- or 7-inch needles (n = 22) than in patients requiring 3.5-inch needles (n = 28). Using linear regression, we determined the formula to predict the needle length as Skin-Canal Distance (inches) = 0.077 × Body Mass Index + 0.88. We found a strong correlation (P < .001) between the predicted and actual skin canal distance in 45 patients, and our formula better predicted the skin-canal distance than others. CONCLUSIONS We designed a formula that uses body mass index to predict the appropriate needle length in oblique interlaminar-approach fluoroscopy-guided lumbar punctures and validated it by demonstrating a strong correlation between the predicted and actual skin-canal distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopic-guided lumbar puncture: fluoroscopic time and implications of body mass index--a baseline study.

BACKGROUND AND PURPOSE Fluoroscopic-guided lumbar puncture is an effective alternative to bedside lumbar puncture in challenging patients. However, no published guidelines are available for an acceptable range of fluoroscopic time for this procedure. The purpose of this study was to set department benchmark fluoroscopic times for lumbar puncture, accounting for body mass index in our patient po...

متن کامل

Factors associated with traumatic fluoroscopy-guided lumbar punctures: a retrospective review.

BACKGROUND AND PURPOSE To minimize diagnostic confusion, a CSF specimen should be free from traumatically introduced red blood cells (RBCs). The purpose of this research is to determine if patient age, sex, gauge of the lumbar puncture (LP) needle, or the level of LP is associated with an increased risk for traumatic fluoroscopy-guided LP. MATERIALS AND METHODS Data were collected retrospecti...

متن کامل

Difficult Lumbar Puncture: Pitfalls and Tips from the Trenches.

Lumbar puncture has, for many years, been the responsibility of the internal medicine physician or the neurologist. As more patients have undergone spine surgery and with the current increase in body mass index of the general population, the radiologist has been consulted with increasing frequency to perform lumbar puncture with fluoroscopic guidance. Radiology, in fact, is now the dominant ove...

متن کامل

Randomised controlled trial of atraumatic versus standard needles for diagnostic lumbar puncture.

OBJECTIVE To compare the ease of use of atraumatic needles with standard needles for diagnostic lumbar puncture and the incidence of headache after their use. DESIGN Double blind, randomised controlled trial. SETTING Investigation ward of a neurology unit in a university hospital. PARTICIPANTS 116 patients requiring elective diagnostic lumbar puncture. INTERVENTIONS Standardised protoco...

متن کامل

Lung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided

Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2016