Fast 3-d optical imaging with transient fluorescence signals.
نویسندگان
چکیده
A fast 3-D optical imaging method with use of exogenous fluorescence agent is proposed and demonstrated by simulation in a model tissue. After administration of fluorescent agent, ultrashort near-infrared laser pulses are used to illuminate the tissue and excite fluorescence emission. The transient fluorescence signals are detected on the tissue boundaries and employed to reconstruct a 3-D image of relative fluorescence emission distribution inside the tissue. A region with greater fluorescence emission represents a diseased tissue if the fluorescent agent has a close affinity with the disease. We successfully demonstrated the feasibility of this method in the imaging of a 4x4x4mm(3) tumor embedded at the center of a cubical tissue phantom with an uptake distribution of fluorescent indocyanine green dye. The image reconstruction does not involve any inverse problem. It took less than 5 minutes in a PC for the model imaging problem.
منابع مشابه
Evaluation of Reflection Optical Imaging Characteristics Using Fluorescence with Near Infrared Wavelength at Different Depths of Tissue Equivalent Phantom
متن کامل
Multifocal multiphoton microscopy: a fast and efficient tool for 3-D fluorescence imaging
Multifocal multiphoton microscopy (MMM) is an efficient and technically simple method for generating multiphoton fluorescence images. Featuring the high axial resolution of confocal and multiphoton scanning microscopes, MMM also achieves high speed in 3-D microscopy. In this paper, examples of fast-mode 3-D microscopy are given including imaging of fixed brain tissue as well as living PC12 cell...
متن کاملPosition Control Improvement of Permanent Magnet Motor Using Model Predictive Control
Fast and accurate transient response is the main requirement in electric machine position control. Conventional cascade control structure has sluggish response due to the limitation of inner control loop bandwidth. In this paper, in order to decrease the Permanent Magnet Synchronous Motor (PMSM) transient response time it can be used reference model using feed-forward signals. In this structure...
متن کاملHigh spatiotemporal resolution imaging of fast intrinsic optical signals activated by retinal flicker stimulation
High resolution monitoring of stimulus-evoked retinal neural activities is important for understanding retinal neural mechanisms, and can be a powerful tool for retinal disease diagnosis and treatment outcome evaluation. Fast intrinsic optical signals (IOSs), which have the time courses comparable to that of electrophysiological activities in the retina, hold the promise for high resolution ima...
متن کاملA Thin Layer Imaging with the Total Internal Reflection Fluorescence Microscopy
Total internal reflection fluorescence microscopy (TIRFM) is an optical technique that allows imaging of a thin layer of the sample with a thickness of about 100-200 nm. It is used in science of cell biology to study cellular processes, especially near the membranes of living cells. This method is based on the total internal reflection phenomenon, where the evanescent wave is generated in the l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2004