Simulation study for optimization of X-ray inspection setup applied to CFRP aerostructures

نویسندگان

  • Konstantinos Tigkos
  • Kristina Bliznakova
  • Aris Dermitzakis
  • Nicolas Ducros
  • Ulf Haßler
  • Zacharias Kamarianakis
  • Ahmad Osman
  • Veronique Rebuffel
  • Mathieu Tartare
چکیده

The goal of this contribution is the development and configuration of a simulation scenario for 2-D (radioscopic) and 3-D (computed tomography) X-ray inspection setups for CFRP aerostructures. Characteristics taken into account are object shape, defect types, their form and spectral properties. The simulations are carried out using analytical simulation software. The simulation procedure and preliminary optimization results are illustrated for the case of thermoplast CFRP specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Effects of Field Size on Beam Homogeneity Coefficient in the Superficial Radiotherapy Machine Using Empirical Method and Simulation

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

متن کامل

Fast Reconstruction of CFRP X-ray Images based on a Neural Network Filtered Backprojection Approach

X-ray inspection of Carbon Fiber Reinforced Polymer (CFRP) is time consuming. With classical reconstruction methods, many projections of the object from different orientations are required to obtain high quality reconstructions of the interior fiber composition. In this work, we propose to reconstruct the interior of the CFRP samples with a Neural Network Filtered Backprojection (NN-FBP) method...

متن کامل

Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

Background: Recently, it has been indicated that X-ray coherent scatter from biological tissues can be used to access signature of tissue. Some scientists are interested in studying this effect to get early detection of breast cancer. Since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. Monte Carlo (MC) codes are the best...

متن کامل

Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...

متن کامل

Level of exposure to X-Ray in security gates of Tehran’s Imam Khomeini airport

X-Ray is an ionizing electromagnetic radiation with a wide spectrum. A setting where this radiation is widely used is airport security units. This study was conducted to measure the level of momentary exposure to X-Ray in operators and personnel working in security gates of Imam Khomeini airport. In this cross-sectional study, the X-Ray machines used in security gates of Imam Khomeini airport a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014