Technetium-99m-ethylene-l-l-dicysteine ((99m)Tc-EC) is an agent with a potential for renal imaging. It is reported that EC uses the same tubular transporter system as ortho-hippurate (OIH) and mercaptoacetyltriglycine (MAG3) and that this agent has good imaging properties and higher renal clearance than MAG3. In this study we used (99m)Tc-EC to compare different washout parameters in renal transplanted patients. Sixty nine scans in 55 patients (38 males, 17 females) were performed with (99m)Tc-EC during the follow-up period after kidney transplantation. After bolus injection of 280MBq (99m)Tc-EC, 60x1sec and 29x1min images were taken in anterior position. Perfusions of transplanted kidneys were examined visually and perfusion indices (PI) were calculated according to Hilson's method. The semiquantitative washout parameters such as 20 and 30min to peak activity ratios and 20 and 30min to 3min activity ratios were calculated. The patients were clinically evaluated by nephrologists experienced in renal transplantation cases and followed-up by serum creatinine and blood urea nitrogen determinants which were checked every postoperative day until stabilized to a optimal level for each patient. Two standard deviations above the mean values derived from all cases with normal functioning transplanted kidneys were calculated for each method. Then, these values served as the threshold to differentiate the pathological cases respectively. Of the 69 total studies performed, we found 34 normal kidneys, 14 rejections, 19 acute tubular necrosis (ATN) and 2 cyclosporin A toxicity cases. The number of abnormal cases detected with 30/3min, 30/max, 20/3min and 20/max indices were 27, 26, 24, and 18, respectively. In conclusion, we strongly recommend in studying renal transplants to consider the activity at the 3(rd) min post injection as a reference point instead of the time to maximum activity for washout index calculation. If, for any reason the time to maximum counts using (99m)Tc-(peak activity) is prefered, then the period of study should not be performed for less than 30min to achieve reliable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of the structural and spectral properties for L,L-ethylenedicysteine diethylester (EC) and its complex with Technetium-99m radionuclide

The technetium-99m complex of the L,L-ethylenedicysteine diethylester (EC), of the brain imaging agent, was reported as a good choice for replacement of the renal nuclear medicines like OIH radiopharmaceutical. This present research work studies the structural, electronic and spectral properties of the EC compound and its complex with technetium-99m radionuclide from theoretical insight. All co...

متن کامل

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Hepatobiliary excretion of 99mTc-EC: A potential source of mistake in the interpretation of renal scintigraphy

A 10-year-old boy with a history of bloody discoloration of urine following recent appendectomy was referred to our department for urinary leakage/fistula evaluation. A renal Technetium-99m-L,L-ethylenedicysteine (99mTc-EC) scintigraphy was performed. After injection of radiotracer, a focus of activity appeared in the supralateral part of the right kidney which was confirmed as accum...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

Comparison of the Absorbed Dose for 99mTc-Diethylenetriaminepentaacetic Acid and 99mTc-Ethylenedicysteine Radiopharmaceuticals using Medical Internal Radiation Dosimetry

The aim of this study was the investigation of absorbed dose to the kidneys, spleen, and liver during technetium-99 m ethylene dicysteine and technetium-99 m diethylenetriaminepentaacetic acid ((99m)Tc-EC and (99m)Tc-DTPA) kidney scan. Patients who had been prepared for the kidney scan, were divided into two groups (Groups 1 and 2). The first group (Group 1) and the second group (Group 2) recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of nuclear medicine

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2010