Improving 99mTc-tetrofosmin Myocardial Perfusion Images by Time Subtraction Technique

نویسندگان

  • Yasuyuki Takahashi
  • Hayato Ishimura
چکیده

Quantitative measurement of myocardium perfusion is possible with single photon emission computed tomography (SPECT) using a semiconductor detector. However, accumulation of 99mTc-tetrofosmin in the liver may make it difficult to assess that accurately in the inferior myocardium. Our idea is to reduce the high accumulation in the liver by using dynamic SPECT imaging and a technique called time subtraction. We evaluated the performance of a new SPECT system with a cadmium-zinc-telluride solid-state semiconductor detector (Discovery NM 530c; GE Healthcare). Our system acquired list-mode raw data over 10 minutes for a typical patient. From the data, ten SPECT images were reconstructed, one for every minute of acquired data. Reconstruction with the semiconductor detector was based on an implementation of a 3-D iterative Bayesian reconstruction algorithm. We studied 20 patients with coronary artery disease (mean age 75.4 ± 12.1 years; range 42-86; 16 males and 4 females). In each subject, 259 MBq of 99mTc-tetrofosmin was injected intravenously. We performed both a phantom and a clinical study using dynamic SPECT. An approximation to a liver-only image is obtained by reconstructing an image from the early projections during which time the liver accumulation dominates (0.5~2.5 minutes SPECT image-5~10 minutes SPECT image). The extracted liver-only image is then subtracted from a later SPECT image that shows both the liver and the myocardial uptake (5~10 minutes SPECT image-liver-only image). The time subtraction of liver was possible in both a phantom and the clinical study. The visualization of the inferior myocardium was improved. In past reports, higher accumulation in the myocardium due to the overlap of the liver is un-diagnosable. Using our time subtraction method, the image quality of the 99mTc-tetorofosmin myocardial SPECT image is considerably improved. Keywords—99mTc-tetrofosmin, dynamic SPECT, time subtraction, semiconductor detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

99mTc-Tetrofosmin in Rats

99mTc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of 99mTc-N-DBODC5 with 99mTc-sestamibi and 99mTc-tetrofosmin. Methods: Seventy-five anesthetized Sprague–...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection.

OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging qua...

متن کامل

99mTc-Tetrofosmin SPECT for Discriminating Infarct from Artifact in Fixed Myocardial Perfusion Defects

Soft-tissue attenuation artifacts generally appear as fixed perfusion-scan defects. Gated 99mTc-tetrofosmin SPECT may help differentiate myocardial infarction (MI) from artifacts, as fixed defects with decreased function (wall motion and thickening) probably represent MI, whereas attenuation artifacts represent preserved function. Methods: Ungated stress and gated rest 99mTc-tetrofosmin SPECT w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016