Dynamic evaluation of the loop technique using the U-Clip.

نویسندگان

  • Hideki Moriyama
  • Shigeyuki Tomita
  • Go Watanabe
چکیده

BACKGROUND We set out to evaluate mitral valve repair with the loop technique under dynamic conditions, using a U-Clip to anchor the loop unit to a papillary muscle. METHODS Mitral valve prolapse was artificially developed by resecting 4 chordae tendineae of a resected porcine heart. The loop unit was anchored to the papillary muscle using U-Clips. Each chordal loop was fixed on the prolapsed leaflet. A roller pump perfused the left ventricle. The left ventricular pressure was maintained at 250 mm Hg. Morphological assessment of the loop reconstruction was performed using an endoscope. RESULTS 10 independent chordal reconstructions were performed. In all cases, the loop unit remained anchored against pressures exceeding 250 mm Hg. Upon increasing the water filling volume, rupture of a chorda tendinea occurred in 7 cases, rupture of the papillary muscle occurred in 2 cases, and left ventricle rupture occurred in 1 case. In all rupture cases, the loop unit remained anchored to the papillary muscle. CONCLUSION This dynamic evaluation of the loop technique using U-Clips to anchor the loop unit to a papillary muscle showed that the loop technique using U-Clips is a safe method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

Developing a Mixed Integer Quadratic Programing Model with Integer Numbers for Designing a Dynamic closed-loop Logistics Network

Logistics Network Design includes network configuration decisions having long-standing influences on other tactical and operational decisions. Recently, regarding environmental issues and customer awareness and global warming closed-loop supply chain network design is taken into consideration. The proposed network for the integrated forward and reverse logistics is developed by formulating a cy...

متن کامل

Experiments on Coupled Technique for Adjacent Similar Buildings

Increasing the population, urbanization has led to the rapid construction of buildings. Due to space constraints and an increase in land cost, these buildings are built too close to each other and can cause damage under dynamic actions such as earthquakes. A new technique, known as Structural coupling, has been developed recently, has found very effective in dissipating the dispersive vibration...

متن کامل

Studying Dynamic behavior of Distributed Parameter Processes Behavior Based on Dominant Gain Concept and it’s Use in Controlling these Processes

In this paper, distributed parameter process systems behavior is studied in frequency domain. Based on the dominant gain concept that is developed for such studies, a method is presented to control distributed parameter process systems. By using dominant gain concept, the location of open loop zeros, resulted from the time delay parameter in the process model, were changed from the right half p...

متن کامل

Stabilizing Microgrid Frequency by Linear Controller Design to Increase dynamic response of Diesel Generator frequency Control Loop

In this paper, a distributed generation including diesel generators, wind turbines, and microturbines are introduced, and their mathematical model is described using the Taylor expansion method. With the goal of computational complexity eliminating, the reduced order model (ROM) of microgrid components is considered. The results of the ‌‌studies indicate that the microgrid frequency is unstable...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Asian cardiovascular & thoracic annals

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2014