Monitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography.
نویسندگان
چکیده
Topical trans-dermal delivery of drugs has proven to be a promising route for treatment of many dermatological diseases. The aim of this study is to monitor and quantify the permeability rate of glucose solutions in rhesus monkey skin noninvasively in vivo as a primate model for drug diffusion. A time-domain Optical Coherence Tomography (OCT) system was used to image the diffusion of glucose in the skin of anesthetized monkeys for which the permeability rate was calculated. From 5 experiments on 4 different monkeys, the permeability for glucose-20% was found to be (4.41 +/- 0.28) 10(-6) cm/sec. The results suggest that OCT might be utilized for the noninvasive study of molecular diffusion in the multilayered biological tissues in vivo.
منابع مشابه
Depth-resolved monitoring of glucose diffusion in tissues by using optical coherence tomography.
We demonstrate the capability of the optical coherence tomography (OCT) technique for depth-resolved monitoring and quantifying of glucose diffusion in fibrous tissues (sclera). The depth-resolved and average permeability coefficients of glucose were calculated. We found that the glucose diffusion rate is not uniform throughout the tissue and is increased from approximately 2.39+/-0.73 x 10(-6)...
متن کاملThermal Effect on Monitoring Non-invasive Blood Glucose in Optical Coherence Tomography
Glucose monitoring using optical coherence tomography (OCT) is a noninvasive technique that offers advantages in terms of signal to noise ratio, resolution and depth of penetration. We present a simulation showing the effect of the variation of the patient's temperature on the measurement of blood glucose. OCT thermo optic effects on glucose monitoring are studied. We point out the impact of sk...
متن کاملClinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملSpecificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study.
Noninvasive monitoring of blood glucose concentration in diabetic patients would significantly reduce complications and mortality associated with this disease. In this paper, we experimentally and theoretically studied specificity of noninvasive blood glucose monitoring with the optical coherence tomography (OCT) technique. OCT images and signals were obtained from skin of Yucatan micropigs and...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biophotonics
دوره 3 1-2 شماره
صفحات -
تاریخ انتشار 2010